Key result
Look-Locker T1 mapping strongly correlates with post-contrast MOLLI for highly reproducible ECV quantification.
Why the study?
Are Look-Locker and MOLLI T1 mapping techniques reproducible for quantifying myocardial extracellular volume in patients with cardiomyopathy?
Observational (n=10)
Single-blind
No
Are Look-Locker and MOLLI T1 mapping techniques reproducible for quantifying myocardial extracellular volume in patients with cardiomyopathy?
Look-Locker and MOLLI T1 mapping techniques demonstrate high interobserver and intraobserver reproducibility for evaluating myocardial extracellular volume.
Answers are grounded in this paper and cite their sources.
Both techniques support reproducible ECV research use in cardiomyopathy; leaves open impact on clinical decisions.
T1 Mapping has emerged as a new marker to quantify myocardial extracellular volume (ECV), which is typically increased in the setting of diffuse fibrosis or infiltrative heart diseases. However the reproducibility of the technique is largely unknown. We sought to identify the interobserver, intraobserver variability of different T1 mapping techniques as well as validation of one technique against the standard technique for ECV quantification. We selected 10 patients with the diagnosis of cardiomyopathy (5 with delayed contrast enhancement and 5 without). The Look-Locker (LL) and Modified Look-Locker both precontrast (MOLLI_Pre) and postcontrast (MOLLI_Post) T1 time were measured by 3 investigators blinded to clinical data at 2 different time points. Interobserver and Intraobserver reproducibility were assessed using 2-way ANOVA approach. The ECV was calculated using pre and post contrast T1 and hematocrit. There was a strong correlation between LL T1 and Post-contrast MOLLI(MOLLI_Post) (R2 0.82, p < 0.001) and a modest correlation between MOLLI_post and ECV (R2 = 0.42, p < 0.001). The interobserver and intraobserver variability of the measurements were expressed as standard errors of measurements (SEM) and 95% CI and were summarized in table 1 . MOLLI_Post had the lowest intraobserver and intraobserver variability with minimal detectable change in T1 of 13.8 and 26.1 respectively. ECV showed minimal both interobserver and intraobserver variability. Both LL and MOLLI are highly reproducible technique. LL was strongly correlated with post-contrast MOLLI which is moderately correlated to ECV.
No takes yet. Share an insight, caveat, or question.
Yingchoncharoen et al. (2014) conducted an observational in Cardiomyopathy (n=10). T1 mapping techniques (Look-Locker, MOLLI_Pre, MOLLI_Post) was evaluated on Correlation between Look-Locker T1 and Post-contrast MOLLI (R2 0.82, p=< 0.001). Look-Locker T1 mapping was strongly correlated with post-contrast MOLLI, and both techniques demonstrated high reproducibility for extracellular volume quantification.