Why the study?
Does the use of automated external defibrillators (AEDs) improve outcomes in children 1 to 8 years of age with no signs of circulation?
Does the use of automated external defibrillators (AEDs) improve outcomes in children 1 to 8 years of age with no signs of circulation?
This guideline update supports the use of AEDs in children aged 1 to 8 years with no signs of circulation, provided the device has high specificity for pediatric shockable rhythms.
Answers are grounded in this paper and cite their sources.
Supports AED use in pediatric arrest; extends prior adult guidelines to children 1-8 years with pediatric dosing.
On the basis of the published evidence to date, the Pediatric Advanced Life Support (PALS) Task Force of the International Liaison Committee on Resuscitation (IL-COR) has made the following recommendation (October 2002):• Automated external defibrillators (AEDs) may be used for children 1 to 8 years of age who have no signs of circulation.Ideally the device should deliver a pediatric dose.The arrhythmia detection algorithm used in the device should demonstrate high specificity for pediatric shockable rhythms, ie, it will not recommend delivery of a shock for nonshockable rhythms (Class IIb).In addition:• Currently there is insufficient evidence to support a recommendation for or against the use of AEDs in children Ͻ1 year of age.• For a lone rescuer responding to a child without signs of circulation, the task force continues to recommend provision of 1 minute of CPR before any other action, such as activating the emergency medical services (EMS) system or attaching the AED.• Defibrillation is recommended for documented ventricular fibrillation (VF)/pulseless ventricular tachycardia (VT) (Class I).The American Heart Association makes every effort to avoid any actual or potential conflicts of interest that may arise as a result of an outside relationship or a personal, professional, or business interest of a member of the writing panel.Specifically, all members of the writing group are required to complete and submit a Disclosure Questionnaire showing all such relationships that might be perceived as real or potential conflicts of interest.
No takes yet. Share an insight, caveat, or question.
Samson et al. (2003) conducted a review in Cardiac arrest / no signs of circulation. Automated external defibrillators (AEDs) was evaluated. Automated external defibrillators may be used for children 1 to 8 years of age who have no signs of circulation, ideally delivering a pediatric dose.