Key result
A computer simulation model of nonstationary Doppler ultrasound signals produced spectrogram speckle patterns that compared very well with clinically recorded signals from normal carotid arteries.
A computer simulation model successfully synthesizes nonstationary Doppler ultrasound signals that closely match clinically recorded spectrogram speckle patterns from normal carotid arteries.
Answers are grounded in this paper and cite their sources.
Simulation models may enable Doppler ultrasound research without patient data; leaves open clinical validation beyond normal carotids.
A computer simulation model of the nonstationary Doppler ultrasound signals arising from pulsatile blood flow is presented. The model uses sinusoidal components that are modulated by a power spectral density function that varies over the cardiac cycle. An empirical model consisting of two exponential functions is used to represent both the continuous wave and pulsed Doppler power spectral density for normal carotid arteries. It is shown that the spectrogram speckle patterns of the synthesized Doppler signals compare very well with those clinically recorded.
No takes yet. Share an insight, caveat, or question.
Mo et al. (1989) studied this question. Computer simulation model of nonstationary Doppler ultrasound signals was evaluated on Spectrogram speckle patterns comparison with clinically recorded signals. A computer simulation model of nonstationary Doppler ultrasound signals produced spectrogram speckle patterns that compared very well with clinically recorded signals from normal carotid arteries.
Synapse has enriched 10 related papers. Consider them for comparative context: