Answers are grounded in this paper and cite their sources.
An instrument has been constructed which simultaneously measures optical path length at two wavelengths and so permits determination of average refractive index over the common path and hence distance to1 × 10⁻⁶or better without extensive meteorological observations. Using a He-Ne laser (6328 Å) and a filtered high-pressure mercury arc lamp (3681 Å), the instrument is expected to measure distances to 15 kilometers with accuracies as high as a few parts in ten million. Preliminary measurements over a 5.3-km path give a standard deviation of 0.15 cm, or better than3 × 10⁻⁷.
No takes yet. Share an insight, caveat, or question.
Earnshaw et al. (1967) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: