Key result
Left atrial strain echocardiography demonstrates ~97% feasibility and excellent reproducibility in healthy neonates.
Why the study?
Left atrial strain is promising for assessing diastolic dysfunction, but data in neonates are limited.
What are the feasibility, reproducibility, and reference ranges of left atrial strain in healthy neonates in the first 48 hours of life?
Observational (n=120)
What are the feasibility, reproducibility, and reference ranges of left atrial strain in healthy neonates in the first 48 hours of life?
Left atrial strain measurement is highly feasible and reproducible in neonates, providing reference ranges for the first 48 hours of life.
Answers are grounded in this paper and cite their sources.
Provides normative LASr ranges for neonates with high feasibility; extends echocardiographic tools but clinical utility requires prospective validation.
Left atrial strain (LAS) is the most promising technique for assessment of diastolic dysfunction but few data are available in neonates. Our aim was to assess feasibility and reproducibility, and to provide reference ranges of LAS in healthy neonates in the first 48 h of life. We performed one echocardiography in 30 neonates to assess feasibility and develop a standard protocol for image acquisition and analysis. LAS reservoir (LASr), conduit (LAScd) and contraction (LASct) were measured. We performed echocardiography at 24 and 48 h of life in an unrelated cohort of 90 neonates. Median (range) gestational age and weight of the first cohort were 34.4 (26.4-40.2) weeks and 2075 (660-3680) g. LAS feasibility was 96.7%. Mean (SD) gestational age and weight of the second cohort were 34.2 (3.8) weeks and 2162 (833) g. Mean (SD) LASr significantly increased from 24 to 48 h: 32.9 (3.2) to 36.8 (4.6). Mean (SD) LAScd and LASct were stable: -20.6 (8.0) and -20.8 (9.9), -11.6 (4.9) and -13.5 (6.4). Intra and interobserver intraclass correlation coefficient for LASr, LAScd and LASct were 0.992, 0.993, 0.986 and 0.936, 0.938 and 0.871, respectively. We showed high feasibility and reproducibility of LAS in neonates and provided reference ranges.
No takes yet. Share an insight, caveat, or question.
Ficial et al. (2022) conducted an observational in Healthy neonates (n=120). Left atrial strain (LAS) echocardiography was evaluated on Feasibility of left atrial strain. Left atrial strain echocardiography in healthy neonates during the first 48 hours of life demonstrated high feasibility and excellent intra- and interobserver reproducibility.
Synapse has enriched 10 related papers. Consider them for comparative context: