Key result
Luminal surface LDL concentration runs ~5-14% higher than bulk concentration, varying inversely with shear rate.
Answers are grounded in this paper and cite their sources.
Numerical modeling suggests that concentration polarization of LDL occurs at the arterial wall, which is flow-dependent and may contribute to the localization of atherosclerosis.
The atherogenic lipid concentration at the luminal surface of a blood vessel may vary according to its location in the arterial tree because of regional differences in wall shear rate, blood pressure, and vascular permeability. We therefore hypothesized that these local variations in the luminal surface lipid concentration may contribute to the localization of atherosclerosis. To verify this hypothesis, the transport of low-density lipoproteins from flowing blood to the arterial wall was studied numerically under both steady-state and pulsatile flow conditions. Numerical analysis predicted that "concentration polarization" of LDL may occur in the arterial system under these conditions. In contrast to steady-state flow conditions, the luminal surface LDL concentration varied with time in a cardiac cycle. However, its time-average value was slightly higher than the corresponding value under steady-state flow conditions. The time-average value of the luminal surface LDL concentration was 5 to 14% greater than the bulk concentration in a straight segment of an artery. The luminal surface LDL concentration at the arterial wall was flow-dependent, varying linearly with the filtration rate through the vessel wall and inversely with wall shear rate. This may therefore have some significant implications for the pathogenesis and localization of vascular disorders.
No takes yet. Share an insight, caveat, or question.
Fatouraee et al. (1998) studied Atherosclerosis. Pulsatile flow conditions vs. Steady-state flow conditions was evaluated on Luminal surface LDL concentration. Numerical analysis of LDL transport demonstrated that the time-average luminal surface LDL concentration is 5 to 14% greater than the bulk concentration, varying inversely with wall shear rate.
Synapse has enriched 10 related papers. Consider them for comparative context: