Key result
Isolated mechanical bivalve MVR shows ~87% five-year survival alongside notable non-lethal thromboembolic risk.
Why the study?
The study was conducted to analyze survival and evaluate the structure and likelihood of lethal and non-lethal complications over a five-year period after mitral valve replacement with bicuspid mechanical prostheses.
What are the survival and complication rates over 5 years following isolated mitral valve replacement with mechanical prostheses?
Observational (n=260)
What are the survival and complication rates over 5 years following isolated mitral valve replacement with mechanical prostheses?
Five-year survival after isolated mechanical mitral valve replacement is 86.6%, but patients face significant ongoing risks of thromboembolic and bleeding complications.
Answers are grounded in this paper and cite their sources.
Substantial long-term thromboembolic and bleeding risks after mechanical MVR warrant caution; leaves open optimal strategies for prospective trials.
The aim of the study. To study the structure of lethal and non-lethal complications with an analysis of survival and the likelihood of non-lethal complications after mitral valve (MV) replacement with bicuspid mechanical prostheses over a five-year period. Materials and methods. The data of 260 patients who were treated in the period of 2012–2014 were analyzed a surgical intervention was performed – isolated MV prosthetics with mechanical bivalve prostheses. Among the patients, there were 84 (32.3 %) men and 176 (67.7 %) women. The median age was 51.0 [44.0–55.5] years. Statistical analysis was carried out using IBM SPSS Statistics 26.0 (USA). Results of the study and conclusions. According to the results of the five-year survival after MV prosthetics with mechanical prostheses, it was 86.6 %. At the same time, acute cardiovascular diseases (myocardial infarction, cardiac arrhythmias) were the leading cause of death. Among non-lethal thromboembolic complications, acute cerebrovascular accident prevailed, it developed in 65.3 %. Among nonlethal hypocoagulation complications, nosebleeds were most often recorded – in 40.5 % of patients. The probability of developing non-lethal thromboembolic complications by the fifth year is 20.0 % vs 18.5 % in the first six months after prosthetics with mechanical prostheses. And the probability of developing non-lethal hypocoagulation complications by the fifth year is 26.8 % vs 6.1 % in the first six months after prosthetics with mechanical prostheses.
No takes yet. Share an insight, caveat, or question.
Markova et al. (2022) conducted an observational in Mitral valve replacement (n=260). Isolated mitral valve replacement with mechanical bivalve prostheses was evaluated on Five-year survival. Following isolated mitral valve replacement with mechanical bivalve prostheses, five-year survival was 86.6%, and the probability of non-lethal thromboembolic complications reached 20.0%.
Synapse has enriched 10 related papers. Consider them for comparative context: