Key result
Retained wire technique successfully extracts a malpositioned transarterial pacing lead.
Why the study?
Inadvertent lead malposition in the arterial system carries thromboembolic risks and often requires extraction, but transarterial extraction using the retained wire technique had not been previously reported.
Case Report (n=1)
The retained wire technique can be safely and effectively utilized for the percutaneous extraction of a malpositioned pacing lead in the subclavian artery and left ventricle.
Answers are grounded in this paper and cite their sources.
Feasibility of retained wire technique shown in one case; leaves open safety, efficacy, and need for prospective validation.
Background: Inadvertent lead malposition (ILM) in the left ventricle (LV) via the subclavian artery is a rare complication during the insertion of cardiac implantable electronic devices (CIED). If not identified, there is a risk of systemic thromboembolism. Transarterial pacing lead extraction often requires surgical removal and carries high risks of bleeding and thromboembolism, but percutaneous extraction has also been previously described. Case summary: A 71-year-old female presented with left homonymous hemianopia on Day 1 post-insertion of a dual-chamber permanent pacemaker (PPM). A computed tomography (CT) angiogram of the brain and aortic arch revealed an acute occlusion of a branch of the right posterior circulating artery (PCA) and a malpositioned pacing lead in the left subclavian artery. Urgent percutaneous removal of the transarterial lead using the retained wire technique was successfully performed. Discussion: Inadvertent lead malposition in the arterial system is rare and often requires lead extraction due to systemic thromboembolic complications. The retained wire technique has been previously described for percutaneous transvenous lead extraction and exchange, but to our knowledge, we are the first to report utilizing this technique for transarterial lead extraction. Using a case report, we highlight the utility, safety, and effectiveness of the retained wire technique in extracting a malposition lead in the subclavian artery and LV.
No takes yet. Share an insight, caveat, or question.
Ng et al. (2022) conducted a case report in Inadvertent lead malposition in the left ventricle via the subclavian artery (n=1). Percutaneous extraction using the retained wire technique was evaluated on Successful percutaneous removal of the transarterial lead. Percutaneous extraction of a malpositioned transarterial pacing lead using the retained wire technique was successfully performed in a 71-year-old female.
Synapse has enriched 10 related papers. Consider them for comparative context: