Key result
Percutaneous removal of an inadvertent LV pacemaker lead using Sentinel cerebral protection succeeds without complications.
Why the study?
Inadvertent pacemaker lead misplacement in the left ventricle can cause thromboembolic events, valvular damage, and endocarditis.
Case Report (n=1)
No
Answers are grounded in this paper and cite their sources.
The use of a cerebral protection system during percutaneous removal of an inadvertently placed left ventricular pacemaker lead may be a safe approach to mitigate stroke risk.
Inadvertent lead misplacement in the left ventricle can lead to thromboembolic events, valvular damage, and endocarditis. We present a case of an inadvertently placed transarterial pacemaker lead in the left ventricle in a patient who underwent percutaneous lead removal. After a multidisciplinary team discussion involving cardiac electrophysiology and interventional cardiology as well as a discussion of treatment options with the patient, it was decided to proceed with pacemaker lead removal with the Sentinel™ Cerebral Protection System (Boston Scientific, Marlborough, MA, USA) to prevent thromboembolic events. The patient tolerated the procedure well without post-procedural complications and was discharged the next day on oral anticoagulation. We also present a step-by-step approach to perform lead removal with the use of Sentinel™, emphasizing mitigating the stroke and bleeding risks in this patient setting.
No takes yet. Share an insight, caveat, or question.
Kewcharoen et al. (2023) conducted a case report in Inadvertently placed transarterial pacemaker lead in the left ventricle (n=1). Percutaneous lead removal with Sentinel Cerebral Protection System was evaluated on Procedural success and complications. Percutaneous removal of an inadvertently placed transarterial pacemaker lead in the left ventricle using the Sentinel Cerebral Protection System was performed successfully without complications.
Synapse has enriched 10 related papers. Consider them for comparative context: