Key result
Worsening LV filling pattern post-TAVI is linked to ~97% higher risk of death or HF hospitalization.
Why the study?
Does worsening of left ventricular filling pattern driven by paravalvular aortic regurgitation after TAVI increase the risk of death or heart failure hospitalization?
Cohort (n=82)
Does worsening of left ventricular filling pattern driven by paravalvular aortic regurgitation after TAVI increase the risk of death or heart failure hospitalization?
Significant paravalvular aortic regurgitation after TAVI is associated with worsening diastolic function parameters, which correlates with higher rates of death or heart failure hospitalization.
Answers are grounded in this paper and cite their sources.
Worsening LV filling after TAVI signals higher paravalvular AR risk and poorer outcome; observational data leave open whether diastolic monitoring should guide intervention.
BACKGROUND: Paravalvular aortic regurgitation after transcatheter aortic valve implantation is associated with a hemodynamic deterioration and a poor outcome. We aim to determine the early hemodynamic effect of paravalvular aortic regurgitation in relation with the change in the left ventricle filling pattern and to assess their clinical outcome. MATERIAL AND METHODS: Eighty-two consecutive patients referred for transcatheter aortic valve implantation were included. Patients were classified according to the change in the left ventricular filling pattern, and significant paravalvular aortic regurgitation (grade ≥ 2) was reported. Follow-up and incidence of death and hospitalization for heart failure were reported. RESULTS: Sixteen patients (19·5%) presented a worsening of left ventricular filling pattern. The incidence of significant paravalvular aortic regurgitation was higher in the group with a worsening of left ventricular filling pattern (56·3% vs. 19·7%; P = 0·009). In the multivariate analysis, the only variable significantly associated with the worsening of left ventricular filling pattern was the significant paravalvular aortic regurgitation (OR 4·84; 95% CI 1·23 - 19·1; P = 0·024). During the follow-up (642·5 days), there was a higher incidence of the endpoint of death or hospitalization for heart failure in the group with a worsening of left ventricular filling pattern (62·5% vs. 31·8%; P = 0·042) and a lower event-free survival rate (long rank test = 0·013). CONCLUSIONS: The presence of a significant paravalvular aortic regurgitation is associated with a worsening in parameters of diastolic function. This finding should alert the cardiologist as patients with a worsening of left ventricular filling pattern present a higher incidence of paravalvular aortic regurgitation and a less favourable outcome.
No takes yet. Share an insight, caveat, or question.
Caballero et al. (2014) conducted a cohort in Transcatheter aortic valve implantation (n=82). Worsening of left ventricular filling pattern vs. No worsening of left ventricular filling pattern was evaluated on Death or hospitalization for heart failure (p=0.042). Worsening of left ventricular filling pattern after TAVI was associated with a higher incidence of death or heart failure hospitalization.
Synapse has enriched 10 related papers. Consider them for comparative context: