Answers are grounded in this paper and cite their sources.
Clogging is a major constraint to the agricultural reuse of produced water; however, ultra-low-frequency dynamic electronic pulses (EPs) can help control biofouling in drip emitters. This study aimed to evaluate the reduction in clogging in non-self-compensating emitters applying onshore oil-and-gas-produced water treated with EP. Three experimental benches were assembled using drip irrigation units supplied with different water sources: water supply (WS), produced water with EP (OPW + EP), and produced water without treatment (OPW). Hydraulic performance was monitored every 40 h for 400 h using average flow rate variation (AFVR), flow variation coefficient (FVC), and distribution uniformity (UD) indices. Data were analyzed using RT-1 analysis with Bonferroni post hoc tests. Results showed that the interaction between water sources and evaluation times significantly (p ≤ 0.01) affected the hydraulic indices. After 400 h, the indices ranked as UD and FVC: WS > OPW + EP > OPW, and AFVR: OPW + EP = WS > OPW. Although OPW presented a low risk of clogging, the application of EP mitigated the obstruction and maintained higher uniformity by reducing clogging. These findings demonstrate that ultra-low-frequency electronic pulses are an innovative anti-clogging technology and provide insights for the sustainable application of produced water.
No takes yet. Share an insight, caveat, or question.
Cruz et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: