Key result
3D TEE detects substantially more Lambl's excrescences and nodules of Arantius than 2D TEE.
Why the study?
Does 3DTEE improve the identification and assessment of Lambl's excrescences and nodules of Arantius on the aortic valve compared to 2DTEE?
Observational (n=7)
Does 3DTEE improve the identification and assessment of Lambl's excrescences and nodules of Arantius on the aortic valve compared to 2DTEE?
3DTEE provides incremental value over 2DTEE for the qualitative and quantitative assessment of small aortic valve structures such as Lambl's excrescences and nodules of Arantius.
3DTEE may detect more aortic valve lesions than 2DTEE; leaves open whether this alters management or warrants routine use.
In this retrospective study, we identified 7 cases where Lambl's excrescences were identified by two-dimensional transesophageal echocardiography (2DTEE) and also had live/real time three-dimensional transesophageal echocardiography (3DTEE) studies available for comparison. We subsequently assessed them for the presence of Lambl's excrescences (LE) and nodules of Arantius (NA) on the aortic valve. After their identification, we qualitatively and quantitatively organized our findings by number, cusp location, measurements, and orientation if applicable. A greater number of LE was found by 3DTEE than 2DTEE (19 vs. 11, respectively). In all 3DTEE studies, their cusp attachment site, their x-, y-, and z-axis measurements, and orientation were clearly visualized and described. Only 3DTEE studies provided confident visualization of the cusp attachment sites. Similarly, a greater number of NA was found by 3DTEE than 2DTEE (21 vs. 5, respectively). The triad of NA was visualized in all 3DTEE studies and each was described using its x-, y-, and z- axis measurements. Only three 2DTEE studies provided reliable identification of the NA. In conclusion, we present further evidence of the incremental value of 3DTEE over 2DTEE in the qualitative and quantitative assessment of cardiac structures including LE and NA on the aortic valve.
No takes yet. Share an insight, caveat, or question.
Dumaswala et al. (2013) conducted an observational in Lambl's excrescences and nodules of Arantius on the aortic valve (n=7). Three-dimensional transesophageal echocardiography (3DTEE) vs. Two-dimensional transesophageal echocardiography (2DTEE) was evaluated on Number of Lambl's excrescences and nodules of Arantius identified. Three-dimensional transesophageal echocardiography identified a greater number of Lambl's excrescences (19 vs. 11) and nodules of Arantius (21 vs. 5) compared to two-dimensional echocardiography.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: