Key result
ICG near-infrared fluorescence imaging reveals distinct perfusion patterns in affected versus unaffected bowel segments.
Why the study?
Quantification of NIR fluorescence signals is pivotal for standardized assessment of tissue perfusion, and the study aimed to emphasize difficulties in quantifying NIR fluorescence imaging for perfusion analysis.
Does quantitative near-infrared fluorescence imaging using indocyanine green improve assessment of bowel perfusion after mesenteric resection?
Case Report (n=4)
Does quantitative near-infrared fluorescence imaging using indocyanine green improve assessment of bowel perfusion after mesenteric resection?
Quantitative analysis of near-infrared fluorescence imaging using indocyanine green highlights the difficulties in interpreting uncorrected fluorescence signals for bowel perfusion assessment.
Quantitative ICG analysis highlights challenges with uncorrected signals; leaves open whether it improves perfusion assessment post-resection.
SIGNIFICANCE: Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) has proven to be a feasible application for real-time intraoperative assessment of tissue perfusion, although quantification of NIR fluorescence signals is pivotal for standardized assessment of tissue perfusion. AIM: Four patients are described with possible compromised bowel perfusion after mesenteric resection. Based on these patients we want to emphasize the difficulties in the quantification of NIR fluorescence imaging for perfusion analysis. APPROACH: During image-guided fluorescence assessment, 5 mg of ICG (2.5 mg / ml) was intravenously administered by the anesthesiologist. NIR fluorescence imaging was done with the open camera system of Quest Medical Imaging. Fluorescence data taken from the regions of interest (bowel at risk, transition zone of bowel at risk and adjacent normally perfused bowel, and normally perfused reference bowel) were quantitatively analyzed after surgery for fluorescence intensity-and perfusion time-related parameters. RESULTS: Bowel perfusion, as assessed clinically by independent surgeons based on NIR fluorescence imaging, resulted in different treatment strategies, three with excellent clinical outcome, but one with a perfusion related complication. Post-surgery quantitative analysis of fluorescence dynamics showed different patterns in the affected bowel segment compared to the unaffected reference segments for the four patients. CONCLUSIONS: Similar intraoperative fluorescence results could lead to different surgical treatment strategies, which demonstrated the difficulties in interpretation of uncorrected fluorescence signals. Real-time quantification and standardization of NIR fluorescence perfusion imaging could probably aid surgeons in the nearby future.
No takes yet. Share an insight, caveat, or question.
Meijer et al. (2021) conducted a case report in Possible compromised bowel perfusion after mesenteric resection (n=4). Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) vs. Unaffected reference segments was evaluated on Fluorescence intensity- and perfusion time-related parameters. Post-surgery quantitative analysis of near-infrared fluorescence imaging using indocyanine green showed different patterns in affected bowel segments compared to unaffected reference segments.