Answers are grounded in this paper and cite their sources.
This review provides a comprehensive analysis of experimental and clinical studies on the use of indocyanine green (ICG) angiography to determine the perfusion level of gastrointestinal tract organs during surgical interventions involving resection and anastomosis. It is demonstrated that intraoperative ICG-based fluorescence angiography is increasingly used in surgical practice worldwide. Of particular scientific and practical interest is the implementation of this technology for the precise selection of anastomosis sites during gastrointestinal tract surgery. Currently, ICG angiography is used primarily in its qualitative (or subjective) form, while the clinical application of quantitative fluorescence curve analysis is still in the stage of exploratory and pilot studies. At present, there is lack of objective criteria (clinical standards) for the quantitative analysis of ICG curves. However, current research results have shown that intraoperative generation and visualization of time-intensity curves, with assessment of the temporal parameters of inflow and maximum fluorescence intensity in real time, allows for an objective assessment of blood supply. In turn it provides an objective way to identify borderline perfusion disorders that are not visible during visual assessment. Further clinical studies with a larger number of observations are needed to assess the prognostic significance and standardize quantitative criteria for evaluating perfusion to prevent anastomotic failure and to assess the extent of resection in cases of acute mesenteric ischemia. To fully realize the diagnostic potential of quantitative angiography with ICG in a real operating room setting, comprehensive improvement of the technology across all its key components is required, namely: 1) optimization of the methods and modes of drug delivery to the target area; 2) consideration of the individual hemodynamic characteristics of the patient and the anatomical location of the anastomosis; 3) combined mathematical integration of the parameters of both arterial inflow and venous outflow; 4) modernization of imaging systems by combining the advantages of qualitative and quantitative methods; 5) refinement of the methodology for evaluating the results of clinical trials based on a differentiated approach to surgeries of various types and levels of complexity. Morphological methods where possible (in experimental studies), should serve as an objective verification tool for comparing the quantitative parameters of ICG angiography with the real degree of bowel wall damage.
No takes yet. Share an insight, caveat, or question.
Papayan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: