Key result
Green synchronous spectrofluorimetry enables simultaneous detection of curcumin and doxorubicin down to 0.009 µg/mL.
Why the study?
Emission spectra overlap prevents simultaneous estimation of co-administered curcumin and doxorubicin by conventional spectrofluorimetry.
A synchronous spectrofluorimetric method was successfully developed and validated for the simultaneous estimation of curcumin and doxorubicin in biological matrices.
Enables simultaneous CUR/DOX quantification in plasma/urine; leaves open routine adoption pending patient-cohort validation.
Recently, phytochemicals play an important role in cancer management. Curcumin (CUR), a natural phytochemical, has been co-administered with widespread chemotherapeutic agents such as doxorubicin (DOX) due to its excellent antitumor activity and the ability to lower the adverse reactions and drug resistance cells associated with DOX use. The present study aims to determine DOX and CUR utilizing a label-free, selective, sensitive, and precise synchronous spectrofluorimetric method. The obvious overlap between the emission spectra of DOX and CUR prevents simultaneous estimation of both analytes by conventional spectrofluorimetry. To solve such a problem, synchronous spectrofluorimetric measurements were recorded at Δλ = 20 nm, utilizing ethanol as a diluting solvent. Curcumin was recorded at 442.5 nm, whereas DOX was estimated at 571.5 nm, each at the zero-crossing point of the other one. The developed method exhibited linearity over a concentration range of 0.04–0.40 μg/mL for CUR and 0.05–0.50 μg/mL for DOX, respectively. The values of limit of detection (LOD) were 0.009 and 0.012 µg/mL, while the values of limit of quantitation (LOQ) were 0.028 and 0.037 µg/mL for CUR and DOX, respectively. The adopted approach was carefully validated according to the guidelines of ICH Q2R1. The method was utilized to estimate CUR and DOX in laboratory-prepared mixtures and human biological matrices. It showed a high percentage of recoveries with minimal RSD values. Additionally, three different tools were utilized to evaluate the greenness of the proposed approach.
No takes yet. Share an insight, caveat, or question.
Dagher et al. (2024) studied this question. Synchronous spectrofluorimetric method was evaluated on Limit of detection (LOD) and limit of quantitation (LOQ). A green synchronous spectrofluorimetric method was developed for the simultaneous estimation of curcumin and doxorubicin, achieving limits of detection of 0.009 and 0.012 µg/mL, respectively.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: