Answers are grounded in this paper and cite their sources.
Virtual impactors (VIs) with both high sampling flow rates and submicrometer cutsizes are desirable to efficiently separate and concentrate particles from an aerosol, towards higher signal in analyses. Increasing the flow rate of round nozzle VIs while maintaining target concentration factor increases in the submicrometer size range requires designing a multiple nozzle system. Meanwhile, slit nozzle VIs can in principle be more easily scaled to higher flow rates by just increasing the length of the slit. Linear slit nozzles, however, introduce edge effects, which can in turn be overcome through the design of circumferential slit nozzle VIs. In this work, building upon recent studies in compressible flow round nozzle VIs with submicrometer cutsizes, we design, simulate, and test VIs using both linear slit nozzles for low-volume sampling rates and circumferential slit nozzles for high-volume sampling rates. First, two virtual impactors (VIs) with linear slit nozzles were designed to evaluate their performance under both incompressible and compressible flow conditions. Experimental results show that increasing the flow rate into the compressible regime shifted the 50 % cutsize into the submicrometer range. Specifically, increasing the sampling flow rate from 12 L min −1 to 40 L min −1 shifted the 50 % cutsize (diameter) of linear slit VI-1 from 1.3 µm to 0.95 µm, while for linear slit VI-2 the cutsize shifted from 1.2 µm to 0.9 µm. A VI with a circumferential slit nozzle, which enables accurate and economical machining and provides a compact design suitable for high-volume sampling rates, was then built and tested. A cutsize of 0.65 µm was achieved when sampling an aerosol flow rate of 720 L min −1 with a minor flow of 72 L min −1 . All experimental performance evaluations were conducted in an ANSI/ASHRAE Standard 52.2-2017 wind tunnel using polydisperse oleic acid particles (0.3 µm to 10 µm) generated by an atomizer. The experimental results indicate that the cutsize of the VI agrees well with predictions. However, the particle collection efficiency curve is less sharp than that of conventional round nozzle VIs. To better understand particle trajectories and losses within the designed virtual impactors, computational fluid dynamics (CFD) simulations coupled with particle trajectory calculations were performed. Simulation results by varying geometries and nozzle alignment indicate that manufacturing tolerances, such as variations in nozzle width along the accelerating nozzle length and misalignment between the accelerating nozzle and the receiving tube, could lead to the reduced sharpness of the collection efficiency curve in slit nozzle VIs.
No takes yet. Share an insight, caveat, or question.
Fu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: