Key result
Femoral artery collapse ratio correlates strongly with ETCO2 as an alternative marker of high-quality CPR.
Why the study?
CPR quality is crucial for improving survival after cardiac arrest, but the usefulness of femoral artery collapse ratio via M-mode ultrasound compared to ETCO2 required evaluation.
Does femoral artery collapse ratio measured by M-mode ultrasound correlate with ETCO2 for assessing CPR quality in a porcine cardiac arrest model?
Does femoral artery collapse ratio measured by M-mode ultrasound correlate with ETCO2 for assessing CPR quality in a porcine cardiac arrest model?
The femoral artery collapse ratio measured by M-mode ultrasound correlates with ETCO2 and may serve as a simple alternative method to evaluate high-quality CPR.
Answers are grounded in this paper and cite their sources.
M-mode femoral collapse ratio warrants human validation as CPR surrogate; porcine data leaves open translation versus ETCO2.
Cardiopulmonary resuscitation (CPR) quality is crucial for improving patient survival rates after cardiac arrest. This study aimed to investigate the usefulness of femoral artery collapse ratio (systolic diameter/diastolic diameter ratio) measurement using M-mode ultrasound versus end-tidal carbon dioxide (ETCO2) for the assessment of high-quality CPR in a porcine cardiac arrest model. A total of 10 male mongrel pigs (age range, 16–20 weeks; weight, 45–50 kg) were used. After anesthesia, the carotid artery was dissected and exposed. The animals were instrumented with an arterial catheter in the exposed carotid artery to monitor arterial blood pressure. Cardiac arrest was induced by injecting potassium chloride (KCl, 40 equivalents of weight). The animals underwent chest compression using a mechanical device, and the chest compression depth and ETCO2 were measured using a defibrillator. To obtain hemodynamic information, two investigators performed an ultrasound examination on both femoral arteries. One examiner measured the femoral peak systolic velocity (PSV), while the other measured the diameters of the femoral artery (systolic diameter and diastolic diameter) in a transverse or longitudinal position using the M-mode of the linear ultrasound probe. As the compression depth increased, ETCO2, femoral artery diameter, collapse ratio (systolic diameter/diastolic diameter), and blood flow increased; however, PSV decreased. The ETCO2 and collapse ratio were positively correlated. The femoral artery collapse ratio, measured using the M-mode ultrasound, could be an alternative and simple method to evaluate high-quality CPR.
No takes yet. Share an insight, caveat, or question.
Min et al. (2023) studied Cardiac arrest (n=10). Femoral artery collapse ratio measurement vs. End-tidal carbon dioxide (ETCO2) was evaluated on Correlation between femoral artery collapse ratio and ETCO2 (B 7.935, 95% CI 7.208-8.662, p=<0.001). The femoral artery collapse ratio was correlated with end-tidal carbon dioxide, indicating it could be a simple alternative method to evaluate high-quality CPR.