Key result
Digital BP devices linked to ~89% fewer end-digit zero systolic readings vs mercury devices.
Why the study?
There have been few reports from Africa on the occurrence of end-digit preference in blood pressure measurement by nurses using mercury versus digital devices.
Does a digital blood pressure-measuring device reduce end-digit preference in recorded blood pressure compared to a mercury sphygmomanometer in patients at an HIV/AIDS clinic?
Observational (n=458)
No
Does a digital blood pressure-measuring device reduce end-digit preference in recorded blood pressure compared to a mercury sphygmomanometer in patients at an HIV/AIDS clinic?
The use of digital blood pressure devices significantly reduces end-digit preference compared to mercury sphygmomanometers, improving measurement accuracy.
Answers are grounded in this paper and cite their sources.
Digital devices were associated with reduced end-digit preference in BP readings; leaves open whether this improves outcomes before practice change.
Objectives: When compared with the use of a mercury sphygmomanometer, the use of a validated digital blood pressure (BP) measuring device eliminates the risk of exposure to mercury. Digital devices are also associated with a lesser degree of end-digit preference (EDP). EDP refers to the occurrence of a particular end digit more frequently than would be expected through chance alone. There have been only a few reports from Africa on the occurrence of EDP in BP measurement. This study examined EDP in BP taken by nurses before and after the introduction of a digital BP-measuring device.Design: The design was a retrospective study.Settings and subjects: We reviewed the BP readings of 458 patients who presented at the dedicated clinic for people living with human immunodeficiency virus/acquired immune deficiency syndrome of Ladoke Akintola University of Technology Teaching Hospital, Osogbo, Nigeria, before and after the introduction of the digital BP-measuring device.Outcome measures: The prevalence of end-digit zero of systolic and diastolic BP readings before and after the introduction of the digital device was compared using McNemar's test.Results: There was a large and significant fall in end-digit zero when BP readings that were taken using the mercury and digital devices were compared (systolic 98.1% vs. 10.9%, p-value < 0.001; diastolic 97.1% vs. 14.9%, p-value < 0.001 (McNemar's test).Conclusion: There was a significant reduction in the frequency of end-digit zero when BP was taken with the digital device rather than the mercury device. Regular training and certification of healthcare workers in BP measurement is recommended to ensure a high quality BP measurement standard.
No takes yet. Share an insight, caveat, or question.
Ayodele et al. (2013) conducted an observational in HIV/AIDS (n=458). Digital blood pressure-measuring device vs. Mercury sphygmomanometer was evaluated on Prevalence of end-digit zero of systolic blood pressure readings (p=<0.001). The use of a digital blood pressure-measuring device reduced the prevalence of end-digit zero in systolic readings from 98.1% to 10.9% compared to mercury devices.