Key result
Higher HBP outputs yield greater conduction velocity and more complete BBB correction in two patients.
Why the study?
In heart failure patients with narrow QRS, varying clinical effects were noted depending on His bundle pacing output.
Does varying His bundle pacing intensity output affect conduction velocity and bundle branch block correction in patients requiring pacing?
Case Report (n=2)
Does varying His bundle pacing intensity output affect conduction velocity and bundle branch block correction in patients requiring pacing?
Higher His bundle pacing outputs can result in greater conduction velocity and more complete bundle branch block correction compared to lower outputs.
Answers are grounded in this paper and cite their sources.
May support output titration in select His bundle pacing cases; hypothesis-generating and requires prospective validation before practice change.
Background His bundle pacing (HBP) is considered the most physiological method for cardiac pacing. In heart failure patients with narrow QRS, we noted varying clinical effects depending on HBP output (HIPPOS study ongoing). Here, we report two cases demonstrating how different conduction velocities correspond to different intensities of HBP output. Methods/Results An 82–year–old woman presented with high–grade AV block and narrow QRS. During lead fixation showed initial RBBB morphology, which transitioned to LBBB with stable AV conduction. High output HBP (3.5V/1ms) corrected LBBB. At 3V/1ms an r’ in V1 was observed with a small increase in HV from 44 to 46ms, while at 1.8V/1msec there was a “jump” from 74 to 92ms in RWPT in V6, loosing however the r’in V1. QRS was larger from 74 to 88msec. As output decreased, QRS widened and HV interval varied, with selective HBP at low outputs failing to correct LBBB. In a 76–year–old man with AF and spontaneous RBBB, HBP reduced QRS duration and HV interval as output increased. Lower voltages led to longer QRS and HV intervals, again resulting in selective HBP without RBBB correction before threshold. Results In both cases, the variations in pacing intensity revealed distinct changes in ECG morphology and conduction intervals, highlighting the dynamic relationship between HBP output and myocardial conduction. These observations suggest that incremental adjustments in pacing voltage can modulate the degree of bundle branch block correction, as reflected by alterations in QRS duration, HV interval, and waveform characteristics. Conclusions In both cases there is evidence of conduction system capture from the highest to the lowest voltage. Pacing from high to low voltage in both cases produced multiple ECG morphologies, with evidence that higher HBP outputs result in greater conduction velocity and more complete bundle branch block correction.
No takes yet. Share an insight, caveat, or question.
Katsouras et al. (2026) conducted a case report in Conduction abnormalities (AV block, AF with RBBB) (n=2). His bundle pacing (HBP) was evaluated on ECG morphology and conduction intervals (QRS duration, HV interval). Higher His bundle pacing outputs resulted in greater conduction velocity and more complete bundle branch block correction in two patients.