Key result
Larger false lumen diameter predicts ~288% higher odds of trunk muscle loss in TBAD.
Why the study?
Trunk muscle decrease is associated with adverse outcomes, and acute aortic dissection involves systemic inflammation and prolonged hospitalization that potentially exacerbates muscle size reduction.
Cohort (n=141)
No
In patients with type B acute aortic dissection, a larger false lumen and exaggerated inflammatory response are predictive of significant trunk muscle decrease.
Answers are grounded in this paper and cite their sources.
May aid risk stratification for muscle wasting in type B aortic dissection; leaves open whether targeting inflammation preserves muscle.
Trunk muscle decrease is reportedly associated with an increased risk of multiple adverse clinical outcomes. Acute aortic dissection (AAD) involves a systemic inflammatory response which is associated with exaggerated muscle protein catabolism. AAD requires prolonged hospitalization and potentially exacerbates muscle size decrease.Cross-sectional areas (CSA) of both the bilateral psoas muscle area (PMA) and L4 vertebral body were determined using CT scans on admission to calculate the psoas-lumbar vertebral index (PLVI = bilateral PMA/L4 body CSA) in 141 hospitalized type B AAD patients. Serial CT scans within 30 days were performed to investigate PLVI change (%/day) calculated as: (PLVI at follow-up - PLVI at admission) /PLVI at admission × 100/follow-up interval (days). Patients were categorized into a large decrease of PLVI (LD) group and a modest decrease and increase of PLVI (MDI) group according to the median value of decreased PLVI change (-0.48%/day).A large PLVI decrease was correlated with a higher peak C-reactive protein (CRP) value (13.8 versus 10.9 mg/dL, P = 0.010), and larger false lumen (FL) diameter (13.6 versus 11.4 mm, P = 0.015). The days until ambulation and the length of hospital stay were slightly longer in the LD group than in the MDI group (days until ambulation, P = 0.111; length of hospital stay, P = 0.053). Logistic regression model analysis demonstrated a higher peak CRP level (OR = 3.43; 95% CI, 1.50-7.84) and larger %FL diameter (OR = 3.88; 95% CI, 1.55-9.69) were predictive of a large PLVI decrease.Our results indicate that a larger FL and subsequent exaggerated inflammatory response may result in a trunk muscle decrease in type B AAD patients.
No takes yet. Share an insight, caveat, or question.
Tsuchida et al. (2025) conducted a cohort in Type B Acute Aortic Dissection (n=141). Larger percent false lumen diameter (> median) vs. Smaller percent false lumen diameter (≤ median) was evaluated on Large decrease in psoas-lumbar vertebral index (PLVI) (OR 3.88, 95% CI 1.55-9.69, p=0.004). A larger percent false lumen diameter and higher peak C-reactive protein level were predictive of a large trunk muscle size decrease in patients with type B acute aortic dissection.
Synapse has enriched 10 related papers. Consider them for comparative context: