Key result
Refraction artifact on color flow causes a single ostium secundum ASD to mimic multiple defects.
Case Report (n=1)
Refraction artifacts on color Doppler echocardiography can cause a single ASD to falsely appear as multiple defects, highlighting the need for awareness to avoid misdiagnosis.
Echocardiographers should recognize refraction artifacts to avoid misdiagnosing single ASDs as multiple on color Doppler; this case leaves open their true prevalence and systematic recognition strategies.
Echocardiography is useful for making a diagnosis of atrial septal defect (ASD) by directly visualizing the shunt flow. Herein, we present a case in which a single ostium secundum type ASD masqueraded as multiple defects on color flow imaging by transthoracic echocardiography. We confirmed by transesophageal echocardiography that this patient actually had a single ASD. An echocardiographic refraction artifact was considered to be the cause of this phenomenon. We need to be aware of the existence of this artifact to avoid misdiagnosis. 〈 Learning objective: Echocardiography is useful for making a diagnosis of atrial septal defect (ASD). We present the case with a single ostium secundum type ASD which masqueraded as multiple defects on color flow imaging due to a refraction artifact. Refraction artifacts can make multiple false flow signals on color imaging. This case emphasizes the importance of an understanding of the existence of this artifact in not only B mode imaging but also color Doppler imaging.〉
No takes yet. Share an insight, caveat, or question.
Ochi et al. (2020) conducted a case report in Atrial septal defect (n=1). Echocardiography was evaluated. A single ostium secundum type atrial septal defect masqueraded as multiple defects on color flow imaging due to an echocardiographic refraction artifact.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: