Answers are grounded in this paper and cite their sources.
Simulation study reveals that particle swarm boundary tuning improves settling time in a 48 V synchronous boost converter, indicating robust dynamic regulation under voltage swings.
48 V bus modules must stay regulated under wide input-voltage swings and fast load transients. A proportional-integral (PI) controller and a fuzzy logic controller (FLC) are tuned by the same Particle Swarm Optimization (PSO), a swarm metaheuristic modeled on bird-flock foraging, under an Integral of Time-weighted Absolute Error (ITAE) objective. The novelty is PSO-based membership-boundary optimization: the membership-function limits, analogues of biological decision thresholds, are shaped directly rather than only the scaling gains. A 153 W, 225 kHz synchronous boost converter is simulated with non-ideal parasitics. For input-voltage transitions the PSO-FLC shortens settling time by up to 70.5% (118 versus 400 ms), whereas the PSO-PI gives smaller peak deviation (26.2% versus 40.0%) and faster load-step recovery. Unconstrained, both controllers draw 58–62 A on the worst input-voltage step; a 10 A cycle-by-cycle limit removes these excursions. Under an identical budget and parameter count, boundary tuning attains 12.3% lower ITAE cost and roughly 40% shorter large-signal settling than scaling-gain tuning. Across ten runs the cost varies by under 1.5% of its mean, and the ranking holds at a realizable update rate (4.44 μs, zero-order hold) and under the current limit. The findings are simulation-only comparative design guidance.
No takes yet. Share an insight, caveat, or question.
Karadağ et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: