Answers are grounded in this paper and cite their sources.
Introduction: Total Body Irradiation (TBI) remains a crucial preparatory regimen for hematopoietic stem cell transplantation. However, traditional techniques involve complex workflows requiring dual CT simulations-Head-First Supine (HFS) and Feet-First Supine (FFS)-which pose logistical, dosimetric, and patient comfort challenges. This study introduces a simplified TBI approach using a single HFS CT scan combined with Surface Guided Radiation Therapy (SGRT) for setup verification and intra-fraction motion monitoring on the Radixact® TomoTherapy system. Materials and Methods: From August 2024 to April 2025, five adult patients with hematologic malignancies scheduled for TBI were retrospectively analyzed. Each patient underwent a single HFS simulation scan on PET-CT with full-body coverage. Immobilization was achieved using a vacuum cushion and thermoplastic mask. Treatment planning was performed using Accuray Precision® version 3.5.0.2 on a single CT dataset. Two helical plans, one for the upper body and one for the lower body, were generated with a 14 cm overlap at the mid-thigh. Seven feathered Planning Target Volumes (PTVs) were created at the junction to ensure dose homogeneity. Surface Guided Radiation Therapy (SGRT) was used for initial setup and intra-fraction motion monitoring, while ClearRT-based kVCT imaging served as a secondary internal verification. Patient-specific quality assurance (PSQA) was conducted using Delta4 with 3%/3 mm gamma criteria, and junction dose validation was performed using ion chamber measurements. Results: SGRT enabled accurate patient setup for TBI, with mean translational errors ≤2 mm and rotational errors ≤0.6° when compared to kVCT verification. Real-time motion monitoring during treatment enabled automatic beam-holds with an average latency of 0.0038 seconds, ensuring precise delivery. Dosimetric results showed excellent target coverage (≥95% of the PTV receiving ≥95% of the prescribed dose) and homogeneous dose distribution. Smooth dose profiles were observed at plan junctions, and lung doses remained within safe limits (~1.7 Gy). Pre-treatment QA demonstrated high gamma pass rates across all body regions (mean ≥96.6%), confirming treatment accuracy. Discussion: This simple modified workflow utilizing a single HFS CT scan for full-body TBI on Radixact eliminates the need for patient repositioning and FFS imaging, thereby simplifying the planning and delivery process. Integration of SGRT provides non-ionizing, real-time monitoring, enhancing setup precision and intra-fraction control. The feathered PTV junction design effectively mitigated dose inhomogeneities. This method demonstrates not only dosimetric robustness but also improved workflow efficiency and patient comfort.
No takes yet. Share an insight, caveat, or question.
Nirhali et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: