Key result
Adding atropine to DSE yields similar diagnostic accuracy and complication rates versus conservative protocols.
Why the study?
Does the addition of atropine to dobutamine stress echocardiography improve diagnostic accuracy or increase complication rates compared to conservative protocols in patients evaluated for CAD?
Observational (n=1,090)
No
Does the addition of atropine to dobutamine stress echocardiography improve diagnostic accuracy or increase complication rates compared to conservative protocols in patients evaluated for CAD?
The addition of atropine during dobutamine stress echocardiography does not increase complication rates and provides similar overall diagnostic accuracy, with a trade-off of increased sensitivity and decreased specificity.
Answers are grounded in this paper and cite their sources.
Supports comparable accuracy and safety with atropine addition; leaves open confirmation in randomized CAD trials.
The addition of atropine during dobutamine stress echocardiography (DSE) is increasingly used for detecting coronary artery disease (CAD), but its safety and whether it has added diagnostic accuracy have not been well defined. The aim of this study was to retrospectively compare the complication rate and diagnostic accuracy of three different protocols in the same laboratory. DSE was performed in 1090 patients over a 5-year period. The protocol had included (1) 5' stages up to 30 µg/kg/min of dobutamine in the first 184 patients, (2) 3' stages up to 40 µg/kg/min in the next 274 patients, and (3) 3' stages up to 40 µg/kg/min with atropine, when required in the last 632 patients. A large number of patients (n = 938) underwent coronary angiography within 2 weeks, and 524 patients had a significant coronary stenosis (> 50%). In the whole group of 1090 patients, serious complications developed in 5 patients (one acute myocardial infarction, one sustained ventricular tachycardia, and three prolonged ischemia). Although the incidence was low, there were no detectable differences between protocols. Hypotension, which was defined as a >/= 20 mmHg decrease in systolic blood pressure from the baseline, was observed in 68 patients. Premature ventricular contraction was the most common arrhythmia. The complication rate was similar among three protocols. The diagnostic accuracy for detecting CAD was nearly the same among three protocols (30 µg, 86%; 40 µg, 84%; and 40 µg with atropine, 84%), but the prevalence of CAD was higher with the 30-µg protocol (65%) than the 40-µg protocol (55%) or 40-µg-with-atropine protocol (53%, P < 0.01). In 469 patients without a previous myocardial infarction, the prevalence of CAD was the same (38-42%). Sensitivity increased with more aggressive protocols (71%, 76%, and 84%). However, it was associated with the loss of specificity (92%, 92%, and 85%). Thus, the diagnostic accuracy was similar among groups (84%, 85%, and 84%). In conclusion, the addition of atropine during DSE does not increase the rate of complication compared with previous conservative protocols and shows the same diagnostic accuracy with a small increase in sensitivity at the cost of a small and matched decrease in specificity.
No takes yet. Share an insight, caveat, or question.
Takeuchi et al. (1999) conducted an observational in Coronary artery disease (n=1,090). Dobutamine stress echocardiography with atropine vs. Conservative DSE protocols (30 µg/kg/min or 40 µg/kg/min without atropine) was evaluated on Diagnostic accuracy for detecting coronary artery disease. The addition of atropine during dobutamine stress echocardiography showed similar diagnostic accuracy and complication rates compared to conservative protocols without atropine.
Synapse has enriched 10 related papers. Consider them for comparative context: