Answers are grounded in this paper and cite their sources.
The Chester Step Test (CST) is used in occupational and healthcare settings to estimate cardiovascular fitness (V˙O2max); however, in attempts to overcome V˙O2max- prediction error, a revised version has been developed (CST2). This study investigated the test–retest reliability and criterion validity of the CST2. In a randomized order, at the same time of day, with at least 24 hours rest between trials, 50 healthy participants (32 males, 18 females, age: 34.9 ± 10.9 y, body mass: 79.1 ± 14.5 kg, stature: 174.3 ± 10.9 cm) completed the CST2 twice (CST2a; CST2b) and a treadmill-based V˙O2max test. Test–retest reliability and criterion validity were examined using a repeated measures ANOVA and the 95% limits of agreement (LoA). No significant bias was reported between the CST2a and CST2b predicted and actual V˙O2max (p > .05). The bias ±95% LoA (−0.48 ± 3.4 ml.kg−1.min−1) suggest that the CST2 is a reliable predictor of V˙O2max. However, the bias ±95% LoA between the CST2 predicted and actual V˙O2max ranged from 1.08–1.6 ± 11–11.5 ml.kg−1.min−1, translating to a 31% prediction error. The CST2 is a reliable measure of V˙O2max however should only be considered when an estimate is required.