Key result
Smart shirt sensors demonstrate feasibility for cardiopulmonary coupling analysis with ~17% respiration difference from RIP.
Why the study?
Cardiopulmonary coupling is typically measured using multi-lead electrocardiography and ECG-derived respiration, but novel textile shirts offer convenient sleep monitoring at home, motivating an evaluation of their feasibility for mobile cardiopulmonary coupling analysis.
Is a smart wearable shirt with textile sensors feasible for cardiopulmonary coupling analysis using mobile computing?
Is a smart wearable shirt with textile sensors feasible for cardiopulmonary coupling analysis using mobile computing?
Smart wearables combined with mobile computing demonstrate technical feasibility for cardiopulmonary coupling analysis, potentially enabling home sleep analysis.
Answers are grounded in this paper and cite their sources.
Does not yet support clinical adoption; leaves open validation of textile sensors for home cardiopulmonary monitoring in larger cohorts.
Cardiopulmonary coupling (CPC) analysis links heart and respiration rates to assess sleep-related parameters. Typically, the CPC is measured using multi-lead electrocardiography (ECG) and ECG-derived respiration (EDR). Novel textile shirts with embedded ECG sensors offer convenient and continuously monitored sleep at home. We investigate the feasibility of a shirt with textile sensors (Pro- Kit, Hexoskin, Quebec, Canada) for CPC analysis by mobile computing. ECG data is continuously transmitted from the shirt to a smartphone via Bluetooth Low Energy (BLE). We customize a CPC algorithm and use twelve whole-night recordings from four volunteers to perform qualitative and quantitative analysis. We compare EDR with respiratory inductive plethysmography (RIP). In average, EDR and RIP differ 17.22%. After one night, the batteries are reduced to approx. 70% (shirt) and 90% (smartphone). The run time for CPC processing is approx. 3 min. Hence, smart wearables in combination with mobile computing show technical feasibility for CPC analysis. Eventually, this could yield a useful solution for sleep analysis of non-expert users in a private environment.
No takes yet. Share an insight, caveat, or question.
Schüler et al. (2021) studied Sleep (n=4). Smart shirt with textile sensors (Pro-Kit, Hexoskin) vs. Respiratory inductive plethysmography (RIP) was evaluated on Difference between ECG-derived respiration (EDR) and respiratory inductive plethysmography (RIP) (17.22% difference). A smart shirt with textile sensors demonstrated technical feasibility for cardiopulmonary coupling analysis, with ECG-derived respiration differing from respiratory inductive plethysmography by 17.22%.
Synapse has enriched 10 related papers. Consider them for comparative context: