Key result
Hybrid off-pump CABG and transaortic TAVI proves feasible and complication-free in 4 patients.
Why the study?
Patients with complex coronary artery disease and severe aortic stenosis unsuitable for conventional surgery and transfemoral TAVI pose significant treatment challenges.
Is hybrid off-pump CABG combined with transaortic TAVI feasible and safe in patients with complex CAD and severe AS unsuitable for conventional surgery?
Case Report (n=4)
Is hybrid off-pump CABG combined with transaortic TAVI feasible and safe in patients with complex CAD and severe AS unsuitable for conventional surgery?
Hybrid off-pump CABG combined with transaortic TAVI is a feasible approach for patients with complex CAD and severe AS who are poor candidates for conventional surgery or transfemoral TAVI.
Demonstrates procedural feasibility of hybrid strategies in select high-risk patients; leaves open the need for larger trials on safety and outcomes.
INTRODUCTION: Patients with complex coronary artery disease and severe aortic stenosis unsuitable for conventional cardiac surgery pose a significant treatment challenge. This is especially difficult for patients where percutaneous revascularization is technically very challenging and/or would not offer as complete revascularisation compared to surgical revascularisation. In addition, patients who are unsuitable for transfemoral transcatheter aortic valve implantation (TAVI) pose an additional technical challenge, particularly with dual antiplatelet therapy (DAPT) following percutaneous coronary intervention (PCI). As a potential solution we describe the first case series of hybrid off-pump coronary artery bypass grafting (CABG) combined with transaortic TAVI. METHODS AND RESULTS: Over a ten-month-period, four patients underwent hybrid off-pump CABG combined with transaortic TAVI. A full sternotomy allowed off-pump arterial and vein graft anastomosis to significantly stenosed coronaries. The first three patients had severe aorto-iliac disease precluding femoral access; the fourth patient was deemed unsuitable for PCI. Transaortic TAVI using Edwards Sapien 3 valves were performed without complication in all four patients. CONCLUSION: The hybrid off-pump CABG and transaortic TAVI procedure allows for more complete coronary revascularization, negates the need for DAPT, and minimizes treatment delay of a TAVI procedure, particularly in patients unsuitable for transfemoral access. We propose this as an important treatment option for the heart team to consider.
No takes yet. Share an insight, caveat, or question.
Manoly et al. (2016) conducted a case report in Complex coronary artery disease and severe aortic stenosis (n=4). Hybrid off-pump CABG combined with transaortic TAVI was evaluated on Successful procedure without complication. Hybrid off-pump CABG combined with transaortic TAVI was successfully performed without complication in all 4 patients with complex coronary artery disease and severe aortic stenosis.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: