The cantilever bending beam technique was applied to measure film stress, film magnetization and magneto-elastic coupling in nanometre Fe films grown epitaxially on W substrates. A simple optical deflection technique yielded sub-monolayer sensitivity for stress measurements and was used to determine magnetization and magnetostrictive properties of nanometre Fe films in situ . The combination of an electromagnet inside an ultra-high-vacuum chamber with a rotatable external magnet was employed to perform magneto-optical Kerr-effect measurements in the transversal, longitudinal and polar geometry in fields of up to 0.4 T. Examples for stress-driven structural changes in monolayer Fe films are discussed with respect to the unusual high coercivity found for sesquilayer Fe films and the re-orientation of the easy axis of magnetization in Stranski-Krastanov Fe films. The direct correlation between strain and magnetism was exploited to measure the magnetostrictive bending of the film-substrate composite. The magnitude and sign of the magneto-elastic coupling coefficient were found to depend on the film thickness, in contrast to the respective bulk values.