Key result
3D modeling shows PV and LA electrical heterogeneity and conduction anisotropy generate high-frequency re-entrant sources.
Why the study?
Mechanisms underlying the genesis of re-entrant substrate for atrial fibrillation are not well understood.
This computational model suggests that electrical heterogeneity and conduction anisotropy between pulmonary veins and left atrial tissues are primary drivers of high-frequency re-entrant sources in atrial fibrillation.
Hypothesis-generating for AF reentry mechanisms; leaves open validation in human electrophysiology before guiding ablation.
Mechanisms underlying the genesis of re-entrant substrate for the most common cardiac arrhythmia, atrial fibrillation (AF), are not well understood. In this study, we develop a multi-scale three-dimensional computational model that integrates cellular electrophysiology of the left atrium (LA) and pulmonary veins (PVs) with the respective tissue geometry and fibre orientation. The latter is reconstructed in unique detail from high-resolution (approx. 70 μm) contrast micro-computed tomography data. The model is used to explore the mechanisms of re-entry initiation and sustenance in the PV region, regarded as the primary source of high-frequency electrical activity in AF. Simulations of the three-dimensional model demonstrate that an initial break-down of normal electrical excitation wave-fronts can be caused by the electrical heterogeneity between the PVs and LA. High tissue anisotropy is then responsible for the slow conduction and generation of a re-entrant circuit near the PVs. Evidence of such circuits has been seen clinically in AF patients. Our computational study suggests that primarily the combination of electrical heterogeneity and conduction anisotropy between the PVs and LA tissues leads to the generation of a high-frequency (approx. 10 Hz) re-entrant source near the PV sleeves, thus providing new insights into the arrhythmogenic mechanisms of excitation waves underlying AF.
No takes yet. Share an insight, caveat, or question.
Aslanidi et al. (2013) studied Atrial fibrillation. Three-dimensional computational model was evaluated on Mechanisms of re-entry initiation and sustenance in the pulmonary vein region. A three-dimensional computational model demonstrated that electrical heterogeneity and conduction anisotropy between pulmonary veins and left atrial tissues generate high-frequency re-entrant sources.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: