Answers are grounded in this paper and cite their sources.
Cross-turn-on happens in a phase leg comprising high-side switch(es) and low-side switch(es) when the turn-on of one switch inadvertently triggers the channel current to flow in the off-switch. The terminal current does not reflect the internal channel current because of the numerous parasitic inductances from the package. Detection of the cross-turn-on in a power module is difficult since the dice are usually encapsulated and the channel currents are hard to measure. A nonintrusive method to identify the cross-turn-on based on the changing ringing current is introduced in this paper. The detection method is analyzed theoretically and validated by experiments using a 1.2-kV SiC module. The negative drive voltage and gate resistance for safe operation can be determined by the detection method.
No takes yet. Share an insight, caveat, or question.
Miao et al. (2017) studied this question.