Why the study?
Coronary angiogram visual assessment by cardiologists lacks standardization for evaluating the severity of coronary artery disease stenoses.
Does an AI video model (DeepCoro) improve the precision and reliability of stenosis assessment in coronary angiographies compared to traditional cardiologist assessments?
Observational (n=10,330)
No
Does an AI video model (DeepCoro) improve the precision and reliability of stenosis assessment in coronary angiographies compared to traditional cardiologist assessments?
Effect estimate: MAE 20.15% (95% CI 19.88-20.40)
DeepCoro is a video-based AI tool that enhances the precision and reliability of coronary stenosis assessment compared to traditional visual evaluation by cardiologists.
The coronary angiogram is the gold standard for evaluating the severity of coronary artery disease stenoses. Presently, the assessment is conducted visually by cardiologists, a method that lacks standardization. This study introduces DeepCoro, a ground-breaking AI-driven pipeline that integrates advanced vessel tracking and a video-based Swin3D model that was trained and validated on a large dataset comprised of 182,418 coronary angiographies spanning 4 years. DeepCoro achieved a notable precision of 71.89% in identifying coronary artery segments and demonstrated a mean absolute error of 20.15% (95% CI: 19.88-20.40) and a classification AUROC of 0.8294 (95% CI: 0.8215-0.8373) in stenosis percentage prediction compared to traditional cardiologist assessments. When compared to two expert interventional cardiologists, DeepCoro achieved lower variability than the clinical reports (19.09%; 95% CI: 18.55-19.58 vs 21.00%; 95% CI: 20.20-21.76, respectively). In addition, DeepCoro can be fine-tuned to a different modality type. When fine-tuned on quantitative coronary angiography assessments, DeepCoro attained an even lower mean absolute error of 7.75% (95% CI: 7.37-8.07), underscoring the reduced variability inherent to this method. This study establishes DeepCoro as the first video-based, adaptable tool in coronary artery disease analysis, significantly enhancing the precision and reliability of stenosis assessment.
No takes yet. Share an insight, caveat, or question.
Avram et al. (2023) conducted an observational in Coronary Artery Disease (n=10,330). DeepCoro (AI video model) vs. Traditional cardiologist visual assessment was evaluated on Stenosis percentage prediction (Mean Absolute Error) (MAE 20.15%, 95% CI 19.88-20.40).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: