Key result
DeepCORO-CLIP predicts 1-year cardiovascular events from whole angiograms better than clinical models with ~0.79 AUROC.
Why the study?
Does the DeepCORO-CLIP multiview video-text model accurately detect obstructive coronary stenosis and predict 1-year cardiovascular events from invasive angiography compared to standard models and cardiologists?
Observational (n=28,117)
Blinded review
Yes
Does the DeepCORO-CLIP multiview video-text model accurately detect obstructive coronary stenosis and predict 1-year cardiovascular events from invasive angiography compared to standard models and cardiologists?
Effect estimate: AUROC 0.79 (95% CI 0.74-0.84)
A novel multiview video-text AI model can accurately detect obstructive coronary disease, characterize lesion features, and predict 1-year clinical outcomes directly from whole invasive angiographic studies.
Invasive coronary angiography is the reference standard for diagnosing coronary artery disease, yet assessment is subjective, and existing artificial-intelligence tools typically assess stenosis in individual frames or videos and do not integrate the full multiview angiographic study. Here we show that DeepCORO-CLIP, trained on 203,808 angiographic videos and reports from 28,117 patients, interprets whole multiple-video angiograms at once. It detects obstructive stenoses (≥70%), with an area under the receiver operating characteristic curve (AUROC) of 0.89 internally and externally, and identifies chronic total occlusion (AUROC = 0.90 to 0.95), intra-coronary thrombus and calcification (AUROC = 0.90 to 0.91). It also predicts 1-year cardiovascular events (AUROC = 0.79, 95% CI of 0.74 to 0.84, versus 0.65 for a model derived using clinical variables) and left ventricular ejection fraction (mean absolute error 7.3% versus 8.8% for a previous model), both achieved using coronary angiography alone. In a blinded review of 365 evaluations across 288 angiograms, its reports were clinically usable in 76% of evaluations versus 88% for cardiologists, with comparable false positives (17% versus 14%, P = 0.38); residual missed stenoses reflected an adjustable threshold rather than an absent signal.
No takes yet. Share an insight, caveat, or question.
Harrabi et al. (2026) conducted an observational in Coronary artery disease (n=28,117). DeepCORO-CLIP vs. Clinical variables model and cardiologists was evaluated on Prediction of 1-year cardiovascular events (AUROC 0.79, 95% CI 0.74-0.84). DeepCORO-CLIP interpreted whole angiograms to detect obstructive stenoses (AUROC 0.89) and predicted 1-year cardiovascular events better than a clinical model (AUROC 0.79; 95% CI 0.74-0.84).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: