Answers are grounded in this paper and cite their sources.
The Editor, The Rusch Flexi-Slip stylet (RFSS) is an accessory intubation tool that consists of a malleable coated wire and a soft atraumatic tip.[1] It has been used as a stylet for the insertion of tracheal tubes and laryngeal mask airway.[1,2] We report a case of difficult intubation where we successfully used the RFSS as a tracheal tube introducer. A 45-year-male was scheduled for coiling of the anterior communicating artery aneurysm under general anaesthesia in the digital subtraction angiography suite. Airway examination revealed Mallampati Grade 3 with a normal mouth opening. After preoxygenation, anaesthesia was induced with intravenous fentanyl (100 μg), propofol titrated to the loss of verbal response followed by administration of vecuronium to facilitate endotracheal intubation. Macintosh laryngoscopy revealed a Cormack–Lehane Grade 3 with a large floppy epiglottis. Two failed attempts of endotracheal intubation using RFSS in situ (RFSS; no. 503,000–4.3/5.6; Willy Rusch GmbH, Kernen, Germany) [Figure 1a] in a flexometallic endotracheal tube (ETT) size 8 mm internal diameter were made, following which the bag and mask ventilation was recommenced. The RFSS was then modified as a bougie with the tip curved to 90° [Figure 1b]. The passage of the RFSS through the trachea was confirmed using careful tactile feedback. The ETT was then railroaded over the RFSS Supplementary Figure 1. The ETT position was confirmed by capnography, bilateral symmetrical air entry and chest rise. The further course was uneventful.Figure 1: Rusch Flexi-Slip Stylet (a) angulated to 90° (b) with the non-traumatic tip (c)Supplementary Figure 1: Depiction of the utility of the Rusch Flexi-Slip Stylet (RFSS) as a boughie. (a) RFSS inserted as a bougie into the glottic aperture using a C-MAC® D-Blade (Karl Storz, Tuttlingen, Germany) video laryngoscope. (b) Railroading the flexo-metallic endotracheal tube over the RFSS which demonstrates sufficient length of the RFSS for control of the endotracheal tube. (c) The insertion of the flexo-metallic endotracheal tube over the RFSS beyond the vocal cords. (d) Videolaryngoscope-guided confirmation of the insertion of the endotracheal tubeTraditionally, a stylet is used for most emergency tracheal intubations, whereas the bougie is reserved for difficult intubations. However, the incidence of first-attempt intubation using video-laryngoscopy increases with a bougie rather than an ETT with stylet in situ.[2] In this case, the video-laryngoscope was not available, so two attempts were made with Macintosh laryngoscopy. Most bougies are associated with a thinner profile and can be passed under full or partial vision or even blindly through the vocal cords providing a scaffold for the passage of an ETT.[3] The most common difficulty in bougie-assisted intubation is the inability to insert the bougie past the hypopharynx (14.8%) as it can bend during the attempt to direct it anteriorly.[4] The RFSS is made of a malleable nylon-coated metal wire which holds its shape to facilitate intubation as comparable to the conventional flexible bougies.[1] The tip of the RFSS was angulated anteriorly, thereby facilitating placement through the vocal cords. This flexibility may facilitate maneuvering the RFSS past the hypopharynx as compared to the conventional bougie that has the tip fixed at 30°. The smooth non-traumatic tip of the bougie also minimises the risk of tracheal trauma during intubation [Figure 1c]. However, there is the potential risk of iatrogenic airway injury, pneumothorax, pharyngeal mucosal, tracheal bleeding/perforation and tonsillar injury.[5] Moreover, the relatively short length of the RFSS necessitates the removal of its connector and straightening of the handle to obtain sufficient length for the adequate control of the ETT during insertion. But even so, there is a risk of loss of the airway during railroading ETTs of size 7.5 mm internal diameter and above. An ideal device should be readily available, inexpensive, easy to store and transport and simple to handle. It should be soft enough to prevent airway trauma but firm enough to maintain its shape even after bending (memory effect). Its tip should be soft and curved for easy positioning under the epiglottis even under partial vision and should provide tactile feedback on proper placement. Ideally, it should also allow emergency oxygenation. The safe dual use of RFSS as a stylet and bougie increases its utility in an unanticipated difficult airway scenario. However, its short length limits its universal use as a bougie for safe handling during railroading. The RFSS may be lost in the airway due to its inadequate length, if used as a replacement for a bougie to railroad the ETT. Considering the beneficial role as a bougie in this index case in an emergency scenario, the modification of the length of the RFSS to ensure safety during the railroading of the ETT is necessary. This case report highlights the utility of devices like RFSS with atraumatic tip and flexibility which can be used both as a bougie and stylet for the insertion of ETTs of sizes ≤7 mm internal diameter with length ≤25 cm. Devices with similar features of RFSS but with increased length should be manufactured to ensure better patient safety during the insertion of larger ETTs. Declaration of patient consent The authors certify that they have obtained all appropriate patient consent forms. In the form, the patient has given his consent for his images and other clinical information to be reported in the journal. The patient understands that his name and initials will not be published and due efforts will be made to conceal his identity, but anonymity cannot be guaranteed. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.
No takes yet. Share an insight, caveat, or question.
Reddy et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: