Key result
TEER linked to lower AF burden at 3 months but unsustained at 12 months.
Why the study?
Patients with significant mitral regurgitation often experience atrial fibrillation, but the effects of transcatheter edge-to-edge repair on atrial fibrillation burden remain unknown.
Does transcatheter edge-to-edge repair reduce atrial fibrillation burden in patients with significant mitral regurgitation?
Cohort (n=66)
Yes
Does transcatheter edge-to-edge repair reduce atrial fibrillation burden in patients with significant mitral regurgitation?
p-value: p=0.03
TEER may transiently reduce atrial fibrillation burden at 3 months in patients with severe mitral regurgitation, though this effect was not sustained at 12 months in a small cohort.
BACKGROUND: Patients with significant mitralregurgitation (MR) often experience atrial fibrillation (AF). The effects of transcatheter edge-to-edge repair (TEER) for MR on AF burden is unknown. METHODS: Patients who underwent TEER atthree institutions who also had a cardiac implantable electronic device with aright atrial lead were retrospectively identified. In patients with baseline AF, device data onAF burden and echocardiographic changes were recorded at baseline and 3- and 12-month follow up time points when available. Data is expressed as number (%) and median (interquartile range), withpaired values analyzed using the Wilcoxon signed-rank test. RESULTS: Overall 66 patients wereidentified, of whom 54 (82%) had baseline data on AF available for review. Of these, 18 (33%) had a baseline burden ofAF (median burden 100% [54-100%]). Patients were 77 (71-83) years old, 10 (56%) male, 14 (78%) White, and 3 (17%) Black. A significant reduction in AF burdenwas observed at 3 months (11 patients, p = 0.03) which did not retainsignificance at 12 months (8 patients, p = 0.69). Indexed maximal left atrial volumes did not significantly change inthose with paired studies available (p > 0.35 for both time points). CONCLUSIONS: In this multicenter cohort, one thirdof patients with severe MR undergoing TEER had an AF burden at baseline, whichwas found to be significantly lower at 3 month follow up. Further investigation is needed to confirm thefindings of this small cohort and determine its effects on downstream sequelaeof AF.
No takes yet. Share an insight, caveat, or question.
Trankle et al. (2022) conducted a cohort in Significant mitral regurgitation and atrial fibrillation (n=66). Transcatheter edge-to-edge repair (TEER) was evaluated on Atrial fibrillation burden (p=0.03). Transcatheter edge-to-edge repair significantly reduced atrial fibrillation burden at 3 months (p=0.03) in patients with severe mitral regurgitation, though this was not sustained at 12 months.