Answers are grounded in this paper and cite their sources.
Four situations of multiple disturbances, pulse to pulse, pulse to ultrasonic, ultrasonic to ultrasonic, and triple ultrasonic at different distances have been tested and located by an improved twice‐fast Fourier transform (FFT) algorithm in this article. The spectrum of the phase difference is performed by autocorrelation to improve peak concentration. Location performance decays to 57 m and 181 m when pulse and ultrasonic are applied at 100 km and 90 km simultaneously. Moreover, the energy ratio of one disturbance to others should be no less than 0. 3825 to be correctly located, which means that the number of detectable disturbances limits to three.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2015) studied this question.