Key result
New JCS guideline identifies ~131% higher VF incidence in Class IIa patients versus former guidelines.
Why the study?
The new Japanese Circulation Society guideline updated implantable cardioverter-defibrillator indications for Brugada syndrome, but its usefulness compared with the former guideline required evaluation.
Does the new JCS guideline improve risk stratification for ventricular fibrillation in patients with Brugada syndrome compared to the former guideline?
Cohort (n=234)
Yes
Does the new JCS guideline improve risk stratification for ventricular fibrillation in patients with Brugada syndrome compared to the former guideline?
The new Japanese Circulation Society guideline provides improved risk stratification for ventricular fibrillation in patients with Brugada syndrome compared to the former guideline.
Answers are grounded in this paper and cite their sources.
May refine ICD selection in BrS; supports NG superiority for risk stratification in retrospective multicenter data.
BACKGROUND: The new guideline (NG) published by the Japanese Circulation Society (JCS) places emphasis on previous arrhythmic syncope and inducibility of ventricular fibrillation (VF) by ≤2 extrastimuli during programmed electrical stimulation (PES) for deciding the indication of an implantable cardioverter-defibrillator in patients with Brugada syndrome (BrS). This study evaluated the usefulness of the NG and compared it with the former guideline (FG) for risk stratification of patients with BrS. METHODS AND RESULTS: This was a multicenter (7 Japanese hospitals) retrospective study involving 234 patients with BrS who underwent PES at baseline (226 males; mean age at diagnosis: 44.9±13.4 years). At diagnosis, 46 patients (20%) had previous VF, 100 patients (43%) had previous syncope, and 88 patients (37%) were asymptomatic. We evaluated the difference in the incidence of VF in each indication according to the new and FGs. During the follow-up period (mean: 6.9±5.2 years), the incidence of VF was higher in patients with Class IIa indication according to the NG (NG: 16/45 patients [35.6%] vs. FG: 16/104 patients [15.4%]), while the incidence of VF in patients with other than class I or IIa indication was similarly low in both guidelines (NG: 2/143 patients [1.4%] vs. FG: 2/84 patients [2.4%]). CONCLUSIONS: This study validated the usefulness of the NG for risk stratification of BrS patients.
No takes yet. Share an insight, caveat, or question.
A 2020 study conducted a cohort in Brugada syndrome (n=234). New Japanese Circulation Society Guideline (NG) vs. Former guideline (FG) was evaluated on Incidence of ventricular fibrillation in patients with Class IIa indication. The new Japanese Circulation Society guideline identified a higher incidence of ventricular fibrillation in Class IIa indication patients compared to the former guideline.
Synapse has enriched 10 related papers. Consider them for comparative context: