Key result
RF wires show no significant difference in procedural complications versus CTO wires in PA/IVS.
Why the study?
Percutaneous radiofrequency wire pulmonary valve perforation in pulmonary atresia with intact ventricular septum is a high-risk procedure with uncertain comparative efficacy and complications versus chronic total occlusion wires.
Does radiofrequency wire compared to chronic total occlusion wire affect procedural efficacy and complications in patients with pulmonary atresia with intact ventricular septum?
Observational (n=206)
Yes
Does radiofrequency wire compared to chronic total occlusion wire affect procedural efficacy and complications in patients with pulmonary atresia with intact ventricular septum?
In neonates with pulmonary atresia and intact ventricular septum, CTO wires may offer a clinically relevant reduction in procedural complications compared to RF wires for pulmonary valve perforation, though statistical significance was not reached in this cohort.
Answers are grounded in this paper and cite their sources.
CTO wires may be associated with fewer complications than RF wires for PA/IVS perforation; leaves open need for randomized confirmation.
Background Percutaneous radiofrequency (RF) wire pulmonary valve perforation (PVP) in pulmonary atresia/intact ventricular septum (PA/IVS) is a high-risk procedure. This study compared procedural efficacy and complications between RF and chronic total occlusion (CTO) wire PVP. Methods This multicenter study included patients with PA/IVS who had PVP attempted at 13 centers. Outcomes of interest were efficacy and complications. Univariable logistic regression models were used to estimate odds ratios and risk differences. Results PVP was attempted in 206 patients; median age 3.0 days (1.0-6.0) and weight 3.1 kg (2.7-3.5). The RF PVP was attempted first in 165 (80.0%) patients, CTO in 27 (13.1%), and stiff end of the coronary wire in 14 (6.8%). The procedural success rate of 94% was similar between wire types. CTO group utilized smaller initial valvuloplasty balloons (2.25 mm [2-3] vs 4 mm [3-6]) and >2 balloons in 71% of cases (vs 18% in RF). Overall and major procedural complications occurred in 26.5% versus 12.5% (odds ratios [OR], 2.5 [0.8-11.1]; P = .15) and 14.8% vs 4.2% (OR, 4.0 [0.8-73.2]; P = .18), respectively, of RF versus CTO groups. Major postprocedural complications occurred in 12% versus 4.2% of the RF versus the CTO groups. Cases with multiple (vs single) PVP attempts had higher overall (40.4% vs 17.0%; OR, 3.3 [1.7-6.6]; P < .01) and major (24.6% vs 8.5%; OR, 3.5 [1.5-8.3], P < .01) procedural complication rates. Conclusions PVP remains an effective treatment strategy in PA/IVS. Complication rate differences between CTO and RF wires may be clinically relevant. Further studies with larger cohorts are warranted to confirm findings and guide optimal intervention strategies.
No takes yet. Share an insight, caveat, or question.
Salavitabar et al. (2025) conducted an observational in Pulmonary atresia with intact ventricular septum (PA/IVS) (n=206). Radiofrequency (RF) wire vs. Chronic total occlusion (CTO) wire was evaluated on Overall procedural complications (OR 2.5, 95% CI 0.8-11.1, p=.15). Radiofrequency wire pulmonary valve perforation in PA/IVS resulted in overall procedural complications in 26.5% of cases versus 12.5% with CTO wires.
Synapse has enriched 10 related papers. Consider them for comparative context: