Key result
Trifecta AVR via right anterior minithoracotomy yields ~1% early mortality and low postoperative gradients.
Why the study?
The study was conducted to evaluate early and intermediate outcomes and hemodynamics of the latest-generation Trifecta valve implanted using right anterior minithoracotomy.
Observational (n=175)
No
Isolated aortic valve replacement using the latest-generation biological prosthesis via right anterior minithoracotomy demonstrates low early mortality and excellent hemodynamic performance at up to 3 years of follow-up.
Supports minithoracotomy AVR with Trifecta in selected patients; leaves open need for RCTs on durability versus sternotomy or other valves.
Objective The aim of this study is to evaluate early and intermediate outcomes and hemodynamics of the latest-generation Trifecta valve implanted using right anterior minithoracotomy. Methods We performed a single-center, retrospective, observational study including 175 individuals who underwent isolated minimally invasive aortic valve replacement with the latest-generation Trifecta valves through a right anterior minithoracotomy between January 2016 and January 2019. Exclusion criteria for follow-up echocardiographic study included concomitant procedures, conversion to median sternotomy, and nonsurvival during the index admission. Analyses addressed implantation safety, 30-day and intermediate-term survival and hemodynamic performance of the valves. Results Overall, patients were followed with duration ranging from 0.5 to 3 years. Early (<30 days) mortality occurred in 2 patients (1.1%), and there were 9 (5.1%) late (>30 days) deaths. Early thromboembolic events and postoperative bleeding requiring reoperation occurred at a rate of 4.0% ( n = 7) and 6.2% ( n = 11), respectively. Overall in 175 patients who met inclusion criteria for the follow-up echocardiography study, mean gradients across all valve sizes were 41.3 ± 14.9 (standard deviation) mm Hg preoperatively and remained low at 7.2 ± 3.9 mm Hg with mean effective orifice area of 1.8 ± 0.5 cm 2 on the last follow-up echo. There was 1 case of infective prosthetic endocarditis, which did not require valve explant. There were no reoperations due to valve-related problems during the study period. Conclusions This is the largest series reporting on outcomes of the latest-generation Trifecta valve implanted using right anterior minithoracotomy. Our results demonstrate that this valve can be safely implanted via a minimally invasive approach with excellent early and intermediate outcomes and hemodynamic performance.
No takes yet. Share an insight, caveat, or question.
Amirjamshidi et al. (2020) conducted an observational in Aortic valve disease requiring replacement (n=175). Trifecta valve implanted using right anterior minithoracotomy was evaluated on Implantation safety, 30-day and intermediate-term survival, and hemodynamic performance. Isolated aortic valve replacement using the Trifecta valve via right anterior minithoracotomy was safe, with 1.1% early mortality and low postoperative mean gradients (7.2 ± 3.9 mm Hg).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: