Key result
Adaptive motion artifact reference selection using acceleration and gyroscope signals improves HR estimation accuracy.
Why the study?
The study aimed to identify an appropriate motion artifact reference selection using acceleration and gyroscope signals to improve motion artifact cancelation in wrist-worn photoplethysmography.
An adaptive motion artifact reference selection approach using both acceleration and gyroscope signals improves the accuracy of instantaneous heart rate estimation from wrist-worn photoplethysmography during intensive exercise.
May improve wrist PPG HR tracking during exercise; leaves open optimal motion artifact reference selection for validation.
BACKGROUND AND OBJECTIVE: Recently, various algorithms have been introduced using wrist-worn photoplethysmography (PPG) to provide high accuracy of instantaneous heart rate (HR) estimation, including during high-intensity exercise. Most studies focus on using acceleration and/or gyroscope signals for the motion artifact (MA) reference, which attenuates or cancels out noise from the MA-corrupted PPG signals. We aim to open and pave the path to find an appropriate MA reference selection for MA cancelation in PPG. METHODS: We investigated how the acceleration and gyroscope reference signals correlate with the MAs of the distorted PPG signals and derived both mathematically and experimentally an adaptive MA reference selection approach. We applied our algorithm to five state-of-the-art (SOTA) methods for the performance evaluation. In addition, we compared the four MA reference selection approaches, i.e. with acceleration signal only, with gyroscope signal only, with both signals, and using our proposed adaptive selection. RESULTS: When applied to 47 PPG recordings acquired during intensive physical exercise from two different datasets, our proposed adaptive MA reference selection method provided higher accuracy than the other MA selection approaches for all five SOTA methods. CONCLUSION: Our proposed adaptive MA reference selection approach can be used in other MA cancelation methods and reduces the HR estimation error. SIGNIFICANCE: We believe that this study helps researchers to address acceleration and gyroscope signals as accurate MA references, which eventually improves the overall performance for estimating HRs through the various algorithms developed by research groups.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2022) studied Heart rate estimation during intensive physical exercise (n=47). Adaptive motion artifact reference selection approach vs. Acceleration signal only, gyroscope signal only, or both signals without adaptive selection was evaluated on Heart rate estimation accuracy. An adaptive motion artifact reference selection approach using acceleration and gyroscope signals provided higher accuracy for heart rate estimation than other selection approaches.