Key result
A gyroscope-assisted approach for motion artifact cancellation in wearable PPG sensors exhibited better heart rate estimation performance than an accelerometer-assisted approach during walking.
Why the study?
Does a gyroscope-assisted approach improve heart rate estimation performance compared to an accelerometer-assisted approach in wearable PPG sensors?
Does a gyroscope-assisted approach improve heart rate estimation performance compared to an accelerometer-assisted approach in wearable PPG sensors?
Using a gyroscope rather than an accelerometer for motion artifact cancellation in wearable PPG sensors improves heart rate estimation accuracy during exercise.
Answers are grounded in this paper and cite their sources.
May support gyroscope use in wearable PPG design during activity; leaves open clinical validation and outcome impact.
Wearable reflectance-type photoplethysmography (PPG) sensors, in the form of a band or watch, have recently gained significant attention for real-time heart rate (HR) monitoring applications. To accurately estimate the HR, even during intensive exercise, much effort has focused on simultaneously measured accelerometer signals that cancel out motion artifacts (MAs) from the PPG signal. However, the accelerometer does not always measure true MAs, as it measures not only the acceleration of motion but also gravitational acceleration corresponding to each axis of the accelerometer. In addition, the measured acceleration of the motion itself does not always coincide with the true motion. In this paper, we address the limitations of accelerometers and present an approach using a gyroscope to overcome the issues described. To the best of our knowledge, the limitations of the acceleration signals for MA cancellation have not been addressed in-depth. Here, we describe our developed wearable reflectance-type PPG sensor and compare the HR estimation performance between using a gyroscope and an accelerometer from 24 subjects. Our results showed that the gyroscope-assisted approach exhibited better performance than the accelerometer-assisted approach, especially for an exercise involving walking.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2018) studied this question. Gyroscope-assisted motion artifact cancellation vs. Accelerometer-assisted motion artifact cancellation was evaluated on Heart rate estimation performance. A gyroscope-assisted approach for motion artifact cancellation in wearable PPG sensors exhibited better heart rate estimation performance than an accelerometer-assisted approach during walking.