Key result
Thoracic gyrocardiography achieves ~88% heart rate agreement with ECG during live-fire exercises.
Why the study?
Inertial measurement units offer unobtrusive heart rate assessment for firefighters during wildfire suppression, but intense and irregular body motion severely limits reliable heart rate estimation.
Does intermittent IMU-based heart rate estimation via SCG and GCG provide viable low-motion window coverage and agreement with chest strap ECG in professional firefighters during an outdoor live fire exercise?
Observational (n=6)
Does intermittent IMU-based heart rate estimation via SCG and GCG provide viable low-motion window coverage and agreement with chest strap ECG in professional firefighters during an outdoor live fire exercise?
Intermittent IMU-based heart rate estimation using gyrocardiography at the anterior thoracic region demonstrates practical feasibility and high agreement with ECG during live-fire wildfire suppression when motion quality windowing is applied.
Answers are grounded in this paper and cite their sources.
Low-motion windows may limit intermittent HR estimation in high-intensity scenarios; leaves open larger validation before operational use.
Opportunistic heart rate (HR) assessment in wildfire suppression scenarios could support the evaluation of cardiovascular strain, physiological stress, and potential risk conditions in firefighters operating under extreme loads. Inertial measurement units (IMUs) represent a promising unobtrusive solution, as they can capture cardiac mechanical vibrations through seismocardiography (SCG) and gyrocardiography (GCG), but intense and irregular body motion severely limits reliable HR estimation. This study evaluates the field viability of intermittent IMU-based HR estimation during an outdoor live fire exercise, involving six professional firefighters equipped with two IMUs placed at the jugular (JR) and anterior thoracic (ATR) regions, and a chest strap ECG-derived reference. Motion intensity was quantified using acceleration vector magnitude (VMU), exploring thresholds from 0.001 g to 0.20 g and 5 s to 10 s windows; coverage of low-motion windows was the primary viability outcome. Very strict VMU thresholds (0.001–0.005 g) retained only approximately 2–14% of samples, while coverage increased to about 25% at 0.01 g and approached 70% at 0.20 g. A VMU threshold of 0.05 g with 10 s windows emerged as an in-sample candidate trade-off between window availability and HR agreement. Within these windows, GCG at ATR showed the highest descriptive agreement with ECG, with 88.2% of pooled estimates within ±5 bpm and 89.6% within ±10 bpm. System Usability Scale and Technology Acceptance Model scores indicated high acceptability of the IMU system, supporting the practical feasibility of intermittent IMU-based HR assessment in wildfire operations when motion quality windowing is applied.
No takes yet. Share an insight, caveat, or question.
Pinnelli et al. (2026) conducted an observational in Cardiovascular strain and physiological stress during live-fire wildfire suppression (n=6). Inertial measurement unit (IMU)-based heart rate estimation via seismocardiography (SCG) and gyrocardiography (GCG) at jugular and anterior thoracic regions vs. Chest strap ECG-derived heart rate reference was evaluated on Coverage of low-motion windows (viability outcome) and heart rate agreement with ECG within low-motion windows. IMU-based gyrocardiography at the anterior thorax achieved 88.2% heart rate agreement within ±5 bpm of ECG using 0.05 g motion thresholds during live-fire exercises.
Synapse has enriched 10 related papers. Consider them for comparative context: