In vitro study demonstrates adequate polymerization in student-placed bulk-fill and conventional resin restorations, suggesting both materials are viable for preclinical training.
Objectives A comparable performance between bulk-fill composites (BFCs) and progressively inserted conventional resin composite (CRC) has been observed in previous studies. However, a significant number of dental institutions in India continue to employ incremental techniques for RC restorations during preclinical studies. But as BFCs are gaining popularity, they may soon be a part of the curriculum for dental students. The aim of this study was to assess the microhardness and the polymerization efficiency of bulk-fill composites versus CRC in class II slot preparations restored by second-year dental students on ivorine mandibular first molar teeth with high-intensity (HI) and low-intensity (LI) light-curing units using the standard mesial slot preparation technique. Material and Methods Fifty preclinical dental students of second year of a dental college were recruited for the study on a voluntary basis. During their preclinical instructions, all participants were taught and made to practice the handling and curing techniques for two-surface RC restorations for 4 months. Each student was asked to perform four RC restorations: CRC-HI, CRC-LI, BFC-HI, and BFC LI. Assessment of microhardness was done using the Vickers microhardness (VMH) test. Statistical analysis One-way and multivariate analysis of variance and Bonferroni 's post hoc test tests were used for data analysis. Results The results showed a significant decrease in the VMH readings in the horizontal axis, progressing from the uppermost to the lowermost positions (p > 0.05). In all the examined groups, the VMH values at the deepest reading locations were found to be higher than 80% of the values observed at the occlusal surface reading locations. Statistically significant associations were seen between the RC type and the light source used in the VMH readings conducted (p > 0.05). However, no significant correlation was identified between the type of light source and the vertical VMH readings (p > 0.05). Conclusion Instructing dental students to place RC restorations using CRC or BFC materials together with both HI and LI light-curing protocols is safe and can be considered for preclinical studies.
No takes yet. Share an insight, caveat, or question.
Hassan et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: