Key result
Transaxillary MICS-AVR yields a 1.9% 30-day MACCE rate.
Why the study?
The transaxillary approach for minimally invasive isolated aortic valve replacement is a novel technique with scarce clinical outcome data available.
Does transaxillary minimally invasive cardiac surgery-aortic valve replacement provide safe and effective outcomes in patients requiring isolated aortic valve replacement?
Cohort (n=1,000)
Does transaxillary minimally invasive cardiac surgery-aortic valve replacement provide safe and effective outcomes in patients requiring isolated aortic valve replacement?
Transaxillary minimally invasive cardiac surgery-aortic valve replacement is a safe and effective approach with low 30-day mortality and MACCE rates.
Answers are grounded in this paper and cite their sources.
Supports transaxillary MICS-AVR feasibility in elective isolated cases; leaves open randomized comparisons to sternotomy or other approaches.
OBJECTIVES: The transaxillary concept for minimally invasive cardiac surgery-aortic valve replacement is a new and versatile approach with nearly no visible scars. Due to its novelty, available data in literature are scarce. This study reports clinical outcomes of 1000 consecutive patients. METHODS: Between 2019 and 2023, 4394 patients underwent elective isolated aortic valve procedures, with 2958 (67.5%) transcatheter aortic valve implantation's and 1436 patients surgical aortic valve replacement's (32.5%). Within this period, 1st consecutive 1000 transaxillary isolated minimally invasive cardiac surgery-aortic valve replacement were enrolled. Endocarditis, redo's or combined procedures were excluded. Mean age was 67.9 ± 8.3 years, STS-PROM 1.39 ± 2.89% and EuroScore II 1.65 ± 1.12%. RESULTS: Use of the transaxillary access increased from 18.7% (2019) to 97.8% (2023). Mean procedure time was 127 ± 31 min, and average cross-clamp time was 43 ± 14 min. Used prostheses were rapid deployment (81.1%), sutured biologic (14.5%) or sutured mechanical valves (4.1%). Conversion rate was 1.9%. No patient died intraoperatively. Thirty-day major adverse cardiac and cerebrovascular event was 1.9% including 0.9% mortality, 0.8% perioperative stroke and 0.6% myocardial infarction. Multivariate factors for major adverse cardiac and cerebrovascular event are intraoperative conversion [OR 1.08 (1.00-1.16); P = 0.04], intraoperative transfusions [OR 1.21 (1.07-1.38); P < 0.01] and respiratory failure [OR 1.39 (1.30-1.49); P < 0.01]. Corresponding factors for mortality are diabetes on insulin [OR 1.02 (1.00-1.04); P = 0.03], pure aortic regurgitation for primary indication [OR 1.03 (1.01-1.05); P < 0.01], intraoperative conversion [OR 1.11 (1.07-1.16); P < 0.01], renal failure [OR 1.08 (1.05-1.10); P < 0.01] and respiratory failure [OR 1.22 (1.17-1.26); P < 0.01]. CONCLUSIONS: Transaxillary minimally invasive cardiac surgery-aortic valve replacement is a safe, effective and cosmetically convincing method for surgical aortic valve replacement, having the potential for >95.0% minimally invasive cardiac surgery rate in selected patients.
No takes yet. Share an insight, caveat, or question.
Wilbring et al. (2024) conducted a cohort in Aortic valve disease requiring isolated aortic valve replacement (n=1,000). Transaxillary minimally invasive cardiac surgery-aortic valve replacement was evaluated on 30-day major adverse cardiac and cerebrovascular event (MACCE). Transaxillary minimally invasive surgical aortic valve replacement resulted in a 30-day major adverse cardiac and cerebrovascular event rate of 1.9% and a 30-day mortality rate of 0.9%.
Synapse has enriched 10 related papers. Consider them for comparative context: