Key result
Rapid deployment aortic valve replacement through anterior right thoracotomy was successfully performed in 50 patients with 2% in-hospital mortality and a mean pressure gradient of 10 mm Hg.
Why the study?
The ease of implantation of rapid deployment and sutureless valves has led to adoption of anterior right thoracotomy for aortic valve replacement, but safety and haemodynamic performance data are needed.
Does rapid deployment aortic valve replacement through anterior right thoracotomy provide safe clinical outcomes and good haemodynamic performance in patients requiring aortic valve replacement?
Observational (n=50)
No
Does rapid deployment aortic valve replacement through anterior right thoracotomy provide safe clinical outcomes and good haemodynamic performance in patients requiring aortic valve replacement?
Answers are grounded in this paper and cite their sources.
Rapid deployment aortic valve replacement via anterior right thoracotomy is a safe minimally invasive approach with excellent hemodynamic performance and low in-hospital mortality.
BACKGROUND: The ease of implantation of the rapid deployment (RD) and sutureless valves has contributed to the adoption of anterior right thoracotomy (ART) approach for aortic valve replacement (AVR). AIM OF THE STUDY: This study evaluates the safety and haemodynamic performance of minimally invasive AVR through ART using the RD valves. METHODS: This is a retrospective, single-center review of a total of 50 consecutive patients who received RD-AVR through ART. RESULTS: The median age of patients was 75 years (interquartile range [IQR]: 69-80), and median Euroscore II was 5.1 (IQR: 2.4-7.5). ART RD-AVR was successfully performed in all cases with no conversion to sternotomy, paravalvular leaks or need for valve explantation. The mean size of the implanted valve was 23.2 ± 2.3 mm. In-hospital mortality was 2%. The mean and maximum pressure gradients across the aortic prosthesis were 10 mm Hg (IQR: 9-12) and 19 mm Hg (IQR: 16-23). CONCLUSIONS: Rapid deployment aortic valve replacement can be safely performed through anterior right thoracotomy wit excellent haemodynamic performance and low postoperative complications rate.
No takes yet. Share an insight, caveat, or question.
Sabry et al. (2020) conducted an observational in Aortic valve disease requiring replacement (n=50). Rapid deployment aortic valve replacement through anterior right thoracotomy was evaluated on In-hospital mortality. Rapid deployment aortic valve replacement through anterior right thoracotomy was successfully performed in 50 patients with 2% in-hospital mortality and a mean pressure gradient of 10 mm Hg.