Key result
ACURATE neo2 TAVI shows ~3% 30-day mortality in severe symptomatic AS.
Why the study?
TAVI has become standard treatment for elderly patients with symptomatic severe aortic valve stenosis, but clinical and hemodynamic outcomes with the ACURATE neo2 valve require evaluation.
Does transcatheter aortic valve implantation with the ACURATE neo2 valve improve clinical and hemodynamic outcomes in elderly patients with symptomatic severe aortic valve stenosis?
Cohort (n=120)
Yes
Does transcatheter aortic valve implantation with the ACURATE neo2 valve improve clinical and hemodynamic outcomes in elderly patients with symptomatic severe aortic valve stenosis?
The ACURATE neo2 valve system demonstrates favorable 1-year safety, low mortality, and excellent hemodynamic performance in elderly patients with severe aortic stenosis.
Answers are grounded in this paper and cite their sources.
Supports ACURATE neo2 feasibility in real-world TAVI; observational data leave comparative efficacy open to randomized trials.
BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become standard treatment for elderly patients with symptomatic severe aortic valve stenosis. The ACURATE neo AS study evaluates 30-day and 1-year clinical and hemodynamic outcomes in patients treated with the ACURATE neo2 valve. METHODS: The primary endpoint of this single-arm multicenter study is 30-day all-cause mortality. Other key endpoints include device performance, echocardiographic measures assessed by an independent core laboratory, and VARC-2 clinical efficacy and safety endpoints through 12 months. RESULTS: The study enrolled 120 patients (mean age 82.1 ± 4.0 years; 67.5% female, mean baseline STS score 4.8 ± 3.8%). The VARC-2 composite safety endpoint at 30 days occurred in 13.3% of patients. All-cause mortality was 3.3% at 30 days and 11.9% at 1 year. The 30-day stroke rate was 2.5% (disabling stroke 1.7%); there were no new strokes between 30 days and 12 months. The rate of permanent pacemaker implantation was 15.0% (18/120) at 30 days and 17.8% (21/120) at 1 year. No patients required re-intervention for valve-related dysfunction and there were no cases of valve thrombosis or endocarditis. Patients demonstrated significant improvement in mean aortic valve gradient (baseline 38.9 ± 13.1 mmHg, 1 year 7.8 ± 3.5 mmHg; P < 0.001 in a paired analysis). In the overall population, paravalvular leak was evaluated at 1 year as none/trace in 60.5%, mild in 37.0%, and moderate in 2.5%; no patients had severe PVL. CONCLUSIONS: One-year outcomes from the ACURATE neo AS study support the safety and performance of TAVI with the ACURATE neo2 valve.
No takes yet. Share an insight, caveat, or question.
Möllmann et al. (2021) conducted a cohort in severe symptomatic aortic stenosis (n=120). ACURATE neo2 valve system was evaluated on 30-day all-cause mortality. Transcatheter aortic valve implantation with the ACURATE neo2 valve system resulted in a 30-day all-cause mortality rate of 3.3% in patients with severe symptomatic aortic stenosis.