Key result
The heart rate deflection point was observed in 100% of runners on the track but only 50% on the treadmill, and it was not an accurate predictor of lactate threshold.
Why the study?
Differences in test protocols may explain inconsistent observation of heart rate deflection during incremental running tests and its accuracy in predicting lactate threshold.
Does the heart rate deflection point accurately predict lactate threshold in trained runners across different test protocols?
Does the heart rate deflection point accurately predict lactate threshold in trained runners across different test protocols?
The heart rate deflection point is not a reliable predictor of lactate threshold, and its presence is highly dependent on the specific exercise testing protocol used.
Answers are grounded in this paper and cite their sources.
Test protocol differences may explain variable HR deflection; leaves open reliable LT prediction in runners.
During an incremental run test, some researchers consistently observe a heart rate (HR) deflection at higher speeds, but others do not. The present study was designed to investigate whether differences in test protocols could explain the discrepancy. Additionally, we sought to determine whether the HR deflection point accurately predicts lactate threshold (LT). Eight trained runners performed four tests each: 1) a treadmill test for maximal O(2) uptake, 2) a Conconi test on a 400-m track with speeds increasing approximately 0.5 km/h every 200 m, 3) a continuous treadmill run with speeds increasing 0.5 km/h every minute, and 4) a continuous LT treadmill test in which 3-min stages were used. All subjects demonstrated an HR deflection on the track, but only one-half of the subjects showed an HR deflection on the treadmill. On the track the shortening of stages with increasing speeds contributed to a loss of linearity in the speed-HR relationship. Additionally, the HR deflection point overestimated the LT when a continuous treadmill LT protocol was used. In conclusion, the HR deflection point was not an accurate predictor of LT in the present study.
No takes yet. Share an insight, caveat, or question.
Vachon et al. (1999) studied Healthy trained runners (n=8). Track running test protocol vs. Treadmill running test protocol was evaluated on Presence of heart rate deflection. The heart rate deflection point was observed in 100% of runners on the track but only 50% on the treadmill, and it was not an accurate predictor of lactate threshold.
Synapse has enriched 10 related papers. Consider them for comparative context: