Key result
Temporary transvenous pacing is linked to ~7% mortality and major complications like heart perforation.
Why the study?
Experience and outcomes of temporary transvenous catheter-electrode pacing in patients with various arrhythmias and pacing indications were reviewed to assess safety and complications.
What are the outcomes and complications associated with temporary transvenous catheter-electrode pacing in patients with rhythm disturbances?
Observational (n=91)
What are the outcomes and complications associated with temporary transvenous catheter-electrode pacing in patients with rhythm disturbances?
Temporary transvenous catheter-electrode pacing is an effective intervention for various rhythm disturbances, though it carries risks of major complications including cardiac perforation and infection.
Answers are grounded in this paper and cite their sources.
Warrants caution with temporary pacing in current practice; leaves open need for safer techniques and prospective data.
Experience with 110 separate periods of transvenous cardiac pacing by means of a catheter-electrode in 91 patients has been reviewed. Indications for the use of the catheter-electrode included (1) complete heart block with and without Adams-Stokes syndrome, (2) other arrhythmias with and without cardiogenic syncope, (3) malfunction of previously implanted permanent pacemaker units, and (4) need for pacing during general surgical procedures in patients with a variety of rhythm disturbances. A case illustrating the combined use of drug therapy and catheter-electrode pacing in controlling paroxysmal ventricular tachycardia is presented. Only six deaths occurred in spite of the serious heart disease in all 91 patients in this series. Two were related to complications of temporary transvenous intracardiac pacing. The major complications associated with the procedure included perforation of the heart, bacteremia, acute myocardial infarction, cephalic vein phlebitis, and ventricular tachyarrhythmia. Minor problems were primarily related to equipment failure or positional difficulties with the catheter-electrode and were usually of no serious consequence.
No takes yet. Share an insight, caveat, or question.
Tancredi et al. (1967) conducted an observational in Heart block, arrhythmias, or need for pacing (n=91). Temporary transvenous catheter-electrode pacing was evaluated on Mortality. Temporary transvenous catheter-electrode pacing in 91 patients resulted in 6 deaths, of which 2 were related to pacing complications, alongside major complications like heart perforation.
Synapse has enriched 10 related papers. Consider them for comparative context: