Answers are grounded in this paper and cite their sources.
Experimental evaluation demonstrates distributed thermal automation and fuzzy heat-risk screening across multi-station workstations, highlighting the utility of tracking short-term temperature trends.
This paper presents a three-station Internet of Things (IoT) architecture for distributed thermal monitoring and local heater automation. The scope is deliberately limited to environmental monitoring, hysteresis-control characterization, and heat-risk screening; it is not presented as a complete thermal-comfort assessment or an occupational heat-stress instrument. Each workstation integrates an M5Stack AtomS3 Lite, a DHT22 temperature–humidity sensor installed at approximately 0.8 m above the floor, a relay, and a 1500 W, 110 V heater. Local automatic control uses a 20–25 °C hysteresis band. Embedded acquisition/transmission was configured at 15 s, while accepted cloud records in the analyzed tests had median intervals of 30–31 s. Repeated automatic-control tests were identified for all three stations, yielding seven, five, and nine ON/OFF transition pairs for Stations 1, 2, and 3, respectively. The mean reported ON-transition temperatures were 19.94, 19.96, and 19.72 °C, respectively, whereas mean reported OFF-transition temperatures were 25.20, 25.58, and 25.32 °C. These results characterize the synchronized cloud-reported heater state, not an independently instrumented relay contact. Packet-level ESP-NOW logs were not available; consequently, packet loss and end-to-end latency are not inferred. In response to the thermal-assessment limitations, the fuzzy layer was simplified to Heat Index, a 5 min Heat-Index trend, and a 15 min hot-sample fraction. Estimated WBGT, Discomfort Index, PMV, and PPD were removed from the decision layer. The HeatRiskScore is therefore an operational heat-screening indicator rather than a comfort or occupational-risk metric. Against a simple instantaneous Heat-Index baseline, the fuzzy classifier reproduced all 18 stable/low-exposure synthetic scenarios and escalated 7/18 scenarios under high recent heat exposure and 9/18 under combined high exposure and rising trend, demonstrating the intended temporal added value without claiming external validation. A datasheet-bound uncertainty sensitivity and a 108-case PMV/PPD factorial analysis further quantify the limitations of low-cost sensing and assumed comfort inputs.
No takes yet. Share an insight, caveat, or question.
Varela–Aldás et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: