Key result
Cast Net technique enables safe and efficient retrieval of a lost intracoronary wire-free covered stent.
Why the study?
Intracoronary stent loss without a guidewire is a rare but serious complication requiring effective retrieval techniques.
Case Report (n=1)
The Cast Net technique provides a novel and effective method for retrieving lost wire-free stents during percutaneous coronary intervention.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for wire-free lost stent retrieval; prospective validation required before clinical adoption.
Intracoronary stent loss is a rare but serious complication. Efforts should be made to properly retrieve the lost device. Such a complication could be particularly challenging in absence of a guidewire within the lost stent. We report a case of coronary perforation managed with ping-pong technique. Prolonged balloon inflation was able to seal the perforation. However, the procedure was complicated by intracoronary loss of a wire free covered stent. We describe a new technique that allowed efficient and safe retrieval of the intracoronary lost wire-free stent. We call it the Cast Net technique.
No takes yet. Share an insight, caveat, or question.
Ouerghi et al. (2025) conducted a case report in Intracoronary stent loss (n=1). Cast Net technique was evaluated on Stent retrieval. The novel Cast Net technique allowed for the efficient and safe retrieval of an intracoronary lost wire-free covered stent.