Key result
Mid-ventricular maximum slice volume accurately estimates end-diastolic volume in ~82% of patients with EF ≥55%.
Why the study?
Task force recommendations for end-diastolic and end-systolic cardiac phase selection lack quantitative evidence and have not explored errors from clinical shortcuts.
Do different methods of end-diastolic and end-systolic phase selection impact the accuracy of volumetric evaluation in cardiac MRI?
Observational (n=60)
Do different methods of end-diastolic and end-systolic phase selection impact the accuracy of volumetric evaluation in cardiac MRI?
Mid-ventricular slice volume maximum provides accurate end-diastolic volume estimates, while aortic valve closure should be used for end-systolic volume in patients with reduced EF due to post-systolic shortening.
Answers are grounded in this paper and cite their sources.
Phase selection shortcuts may introduce LV volume errors up to 12 mL; leaves open standardized cine MRI methods pending prospective validation.
PURPOSE: To evaluate the impact of end-diastolic (ED) and end-systolic (ES) cardiac phase selection methods, since task force recommendations have neither provided quantitative evidence nor explored errors introduced by clinical shortcuts. MATERIALS AND METHODS: Multislice, short-axis cine images were collected in 60 clinical patients on a 1.5T scanner. User-initialized active contour segmentation software quantified global left ventricular (LV) volume across all cardiac phases. Different approaches for selection of ED and ES phase were evaluated by quantification of temporal and volumetric errors. RESULTS: For diastole, the mid-ventricular maximum slice volume coincided with maximum global volume in 82.1% of patients with ejection fraction (EF) ≥55% (P = 0.66) and 71.9% of patients with EF <55% (P = 0.28) and is an accurate approximation of maximum global volume while the first and last phases in a retrospectively electrocardiogram (ECG)-gated acquisition introduced differences in cardiac phase selection (P < 0.001) which led to large errors in measured volume in some patients (12.7 and 10.1 mL, respectively). For systole, post-systolic shortening occurred in a significantly higher number of patients with EF <55% (18.9%) compared to 3.6% of patients with EF ≥55% (P = 0.001), which differentially impacted end-systolic volume estimation. CONCLUSION: For end-diastolic phase selection, our results indicated that the use of the mid-ventricular slice volume maximum provided accurate volume estimates, while selection of the first or last cardiac phase introduced differences in measured volume. For end-systolic phase, patients with EF <55% had a higher prevalence of post-systolic shortening, which suggests aortic valve closure should be used to estimate end-systolic volume.
No takes yet. Share an insight, caveat, or question.
Contijoch et al. (2015) conducted an observational in Patients undergoing cardiac MRI (n=60). Mid-ventricular maximum slice volume method vs. First or last phases in retrospectively ECG-gated acquisition was evaluated on Coincidence of mid-ventricular maximum slice volume with maximum global volume in patients with EF ≥55% (p=0.66). Mid-ventricular maximum slice volume coincided with maximum global volume in 82.1% of patients with EF ≥55% and 71.9% with EF <55%, providing accurate end-diastolic volume estimates.
Synapse has enriched 10 related papers. Consider them for comparative context: